Power Supply; Control; X6R/V3R-Fx In Network Applications; Third Party Control - Optocore X6R-FX-16MI Operating Manual

X6r, v3r-fx series
Table of Contents

Advertisement

Power Supply

The device is optionally equipped with two power inputs and power supply units. If one power supply fails, due to
malfunction of the feeding power line or the power supply unit itself, the device will automatically switch over to
the other power supply unit. In order to make the power supply redundant, both power inputs must be connected
to the mains supply, if possible to different phases, power supply systems, or even better, one of them to an
uninterrupted power supply (UPS).
The power supply units operate with mains voltage of 100 ... 240 V and frequency of 50 ... 60 Hz. Thus the
device can be used throughout the world without any modifications or transformers.
Important:
The switched-mode power supplies operate at very high voltages.
Coming into contact with the power supplies can lead to considerable electric shock,
which may result in death.
To prevent electric shock, do not remove any covers of the device.

Control

All system and device parameters are configured using the OPTOCORE CONTROL software.
The system can be configured and controlled centrally, over the Optocore network, with the exception of the initial
configuration of the unique identifier (ID) of the device.
The OPTOCORE CONTROL software is capable of running multiple instances on the same PC or by using the
OPTOCORE CONTROL software's Client/Server mode.
Please note:
Please refer to the Optocore Quick Start Guide for the basic system configuration and
setup.
For more detailed setup please refer to the Optocore Software Manual

X6R/V3R-FX in Network Applications

The monitoring and operational facilities are only available if an X6R/V3R-FX or -TP is connected directly to a PC
via LAN, USB or RS232. In order to connect and control more than one X6R/V3R-FX with a PC the Control is
transmitted through the network. Optocore Control can run multiple times on one PC or use Server Client Mode.

Third Party Control

Third party protocols for device controlling can be used. It is possible to control Optocore preamps directly from
Yamaha, Studer/Soundcraft, SSL, Lawo and Digico consoles with Special Emulation Mode configured. A Multiple
Emulation Mode feature enables to control preamps in Optocore network from four different consoles.

Optocore bandwidth allocation

The standard bandwidth allocation of an Optocore network is as follows:
Audio
RS485 Data
Video
Ethernet
* If the network is used for transport of Ethernet compatible data the capacity is reduced to one CVBS video
channel plus 100 Mbps Fast Ethernet.
Please note:
Optocore R-Series devices equipped with 2Gbit fibre transceivers are required for
2Gbit network operation.
X6R/V3R-FX
256 Channels @ 48 kHz – 1 Gbit network
768 Channels @ 48 kHz – 2 Gbit network
32 Channels
3 CVBS Video Channels *
100 MBit Fast Ethernet *
18 / 28