Diagnostic Chart - Craftsman 139.53930DM Owner's Manual

1/2 hp 315 mhz
Hide thumbs Also See for 139.53930DM:
Table of Contents

Advertisement

Available languages

Available languages

H
li
E
Safety Reversing Sensor
Bell Wire
Your garage door opener is programmed with
self-diagnostic
capabilities. The "Learn" button/diagnostic
LED will flash a number of times then pause signifying it has
found a potential issue. Consult Diagnostic Chart below.
Diagnostic
Chart
Safety reversing
sensors
wire open (broken or
disconnected).
OR
Safety reversing sensors
wire shorted or blacW
white wire reversed.
....
O
Door control or
wire shorted.
°'O
Safety reversing sensors
slightly
misaligned
(dim or flashing
LED).
Motor overheated
or
possible RPM sensor
failure.
Unplug to reset.
........... •
Motor Circuit Failure.
Replace Receiver
Logic Board.
Symptom:
One or both of the Indicator
lights on the safety sensors
do
not glow steady.
• inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white
wires reversed), broken or disconnected wires, replace/attach
as needed.
• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) from
back each of sensor.
• Reattach sending eye to motor unit using shortened wires, if sending eye indicator
light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors, if the
sensor indicator lights do not light, replace the safety sensors.
Symptom:
LED is not lit on door control
• inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together, if motor unit activates,
replace door control.
• if motor unit does not activate, disconnect door control wires from motor unit.
Momentarily short across red and white terminals with jumper wire. If motor unit
activates, replace door control wires.
Symptom:
Sending indicator
light glows steadily, receiving
indicator
light is
dim or flashing.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.
Symptom:
Motor has overheated;
the motor unit does not operate or
trolley is stuck on stop bolt = Motor unit hums briefly;
RPM Sensor =
Short travel 6-8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• if it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace
RPM sensor.
• if motor unit doesn't operate, motor unit is overheated. Wait 30 minutes and retry, if
motor unit still will not operate replace logic board.
Symptom:
Motor unit doesn't operate.
• Replace logic board because motor rarely fails.
34

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents