Model Number Nomenclature - Carrier Aquasnap 30RAP070 Product Data

Air-cooled chillers with puron refrigerant (r-410a) 10 to 90 nominal tons (35 to 316 nominal kw)
Hide thumbs Also See for Aquasnap 30RAP070:
Table of Contents

Advertisement

Model number nomenclature

Air-Cooled AquaSnap Chiller
30RA
Refrigerant Type
P – Puron
®
Unit Sizes
010 025 045 070
015 030 050 080
018 035 055 090
020 040 060
Voltage
1 –
575-3-60
2 –
380-3-60
5 –
208/230-3-60
6 –
460-3-60
Condenser Coil/Low Sound Options
5 –
MCHX, Value Sound Fan
6 –
MCHX, E-coat, Value Sound Fan
D –
MCHX, AeroAcoustic™ Fan
F –
MCHX, E-coat, AeroAcoustic Fan
J –
MCHX, AeroAcoustic Fan, Compressor Blanket(s)
K –
MCHX, E-coat, AeroAcoustic Fan, Compressor Blanket(s)
Revision Level
A –
Current Revision Level
Hydronic System
30RAP010-060
0 –
No Pump
2 –
Single Pump, 1.5 Hp
3 –
Single Pump, 3 Hp
4 –
Single Pump, 3 Hp High Head
5 –
Single Pump, 5 Hp
6 –
Single Pump, 5 Hp High Head
7 –
Single Pump, 7.5 Hp
Z –
Single Pump, 10 Hp
9 –
Dual Pump, 1.5 Hp
B –
Dual Pump, 3 Hp
C –
Dual Pump, 3 Hp High Head
D –
Dual Pump, 5 Hp
F –
Dual Pump, 5 Hp High Head
G –
Dual Pump, 7.5 Hp
H –
Dual Pump, 10 Hp
LEGEND
EMM — Energy Management Module
GFI
— Ground Fault Interrupting
MCHX — Microchannel Heat Exchanger
SCCR — Short Circuit Current Rating
4
®
AQUASNAP
CHILLER MODEL NUMBER DESIGNATION
30RA
P
010
6
D
30RAP070-090
0 –
No Pump
1 –
Single Pump, 3 Hp
2 –
Single Pump, 5 Hp
3 –
Single Pump, 7.5 Hp
4 –
Single Pump, 10 Hp
5 –
Single Pump, 15 Hp
6 –
Dual Pump, 3 Hp
7 –
Dual Pump, 5 Hp
8 –
Dual Pump, 7.5 Hp
9 –
Dual Pump, 10 Hp
B –
Dual Pump, 15 Hp
C –
Single Pump, 3 Hp with VFD
D –
Single Pump, 5 Hp with VFD
F –
Single Pump, 7.5 Hp with VFD
G –
Single Pump, 10 Hp with VFD
H –
Single Pump, 15 Hp with VFD
J –
Dual Pump, 3 Hp with VFD
K –
Dual Pump, 5 Hp with VFD
L –
Dual Pump, 7.5 Hp with VFD
M –
Dual Pump, 10 Hp with VFD
N –
Dual Pump, 15 Hp with VFD
0
6
0
0
0
Packaging/Security Options
0 –
Std Packaging
4 –
Security Grilles/Hail Guards Only
8 –
Skid Only
D –
Skid, Security Grilles/Hail Guards
J –
Skid, Top Crate, Bag
N –
Skid, Top Crate, Bag, Security Grilles/Hail Guards
Controls/Communications Options
0 –
Std
1 –
Std, BACnet Communication
5 –
EMM
6 – EMM,
B –
EMM, GFI
C – EMM, GFI,
H – GFI
J – GFI,
BACnet Communication
Electrical Options
30RAP010-060
0 –
No Disconnect, No Cooler Heater
1 –
No Disconnect, Cooler Heater
D –
Non-Fused Disconnect, No Cooler Heater
F –
Non-Fused Disconnect, Cooler Heater
30RAP070-090
0 – Single Point,
1 – Single Point,
2 – Single Point,
3 – Single Point,
4 – Dual Point,
5 – Dual Point,
Ambient/Capacity Control/Interrupt Options
0 –
Std Comp, Std Interrupt
1 –
Hot Gas Bypass, Std Interrupt
2 –
Digital Comp, Std Interrupt
3 –
Std Comp, High Interrupt
4 –
Hot Gas Bypass, High Interrupt
5 –
Digital Comp, High Interrupt
6 –
Low Ambient, Std Comp, Std Interrupt
7 –
Low Ambient, Hot Gas Bypass, Std Interrupt
8 –
Low Ambient, Digital Comp, Std Interrupt
9 –
Low Ambient, Std Comp, High Interrupt
B –
Low Ambient, Hot Gas Bypass, High Interrupt
C –
Low Ambient, Digital Comp, High Interrupt
D –
Std Comp, Std Interrupt, Suction Service Valve
F –
Hot Gas Bypass, Std Interrupt, Suction Service Valve
G –
Digital Comp, Std Interrupt, Suction Service Valve
H –
Std Comp, High Interrupt, Suction Service Valve
J –
Hot Gas Bypass, High Interrupt, Suction Service Valve
K –
Digital Comp, High Interrupt, Suction Service Valve
L –
Low Ambient, Std Comp, Std Interrupt, Suction Service Valves
M –
Low Ambient, Hot Gas Bypass, Std Interrupt, Suction Service Valves
N –
Low Ambient, Digital Comp, Std Interrupt, Suction Service Valves
P –
Low Ambient, Std Comp, High Interrupt, Suction Service Valves
Q –
Low Ambient, Hot Gas Bypass, High Interrupt, Suction Service Valves
R –
Low Ambient, Digital Comp, High Interrupt, Suction Service Valves
a30-5348
Quality Assurance
Certified to ISO 9001
BACnet Communication
BACnet Communication
No Disconnect, No Cooler Heater
No Disconnect, Cooler Heater
Non-Fused Disconnect, No Cooler Heater
Non-Fused Disconnect, Cooler Heater
No Disconnect, No Cooler Heater
No Disconnect, Cooler Heater

Advertisement