Appendix A - Model Number Nomenclature - Carrier 50FC 08-16 Series Service And Maintenance Instructions

Single package rooftop electric cooling unit with puron (r-410a) refrigerant 7.5 to 15.0 nominal tons
Table of Contents

Advertisement

Position:
Example:
Unit Heat Type
50 – Cooling with Optional Electric Heat
Packaged Rooftop
®
Model Series - WeatherMaker
FC – Standard Efficiency (EcoBlue™ Technology)
Heat Size
- = No heat
(Field Installed Available)
Refrig. Systems Options
M = Two Stage Cooling, Single Circuit
N = Two Stage Cooling, Single Circuit with
Humidi-MiZer
®
system
Cooling Tons
08 = 7.5 tons
09 = 8.5 tons
12 = 10.0 tons
14 = 12.5 tons
16 = 15 tons
Sensor Options
A = None
B = Return Air (RA) Smoke Detector
C = Supply Air (SA) Smoke Detector
D = RA + SA Smoke Detector
E = CO
Sensor
2
F = RA Smoke Detector and CO
Sensor
2
G = SA Smoke Detector and CO
Sensor
2
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch
K = Condensate Overflow Switch and RA Smoke Detector
L = Condensate Overflow Switch and RA and SA Smoke Detectors
M = Condensate Overflow Switch and SA Smoke Detector
N = Condensate Overflow Switch + CO
P = Condensate Overflow Switch + RA Smoke Detector and CO
Q = Condensate Overflow Switch + SA Smoke Detector and CO
R = Condensate Overflow Switch + RA and SA Smoke Detector and CO
Indoor Fan Options
2 = Standard/Medium Static Motor – Vane Axial EcoBlue
3 = High Static Motor – Vane Axial EcoBlue
5 = Standard/Medium Static Motor – Vane Axial EcoBlue and
Filter Status Switch
6 = High Static Motor – Vane Axial EcoBlue and Filter Status Switch
Coil Options – (Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
APPENDIX A — MODEL NUMBER NOMENCLATURE
1
2
3
4
5
6
7
8
5
0
F
C
-
M
0
8
Sensor
2
2
2
2
Fig. A — Model Number Nomenclature
9 10 11 12 13 14 15 16 17 18
A
2
A
5
-
8
A
0
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
5 = Hinged Access Panels and
6 = 4" MERV 13 High Efficiency Filter Track
7 = Unpowered Convenience Outlet and 4" MERV 13
8 = Powered Convenience Outlet and 4" MERV 13
9 = Hinged Access Panels and 4" MERV 13 High
A = Hinged Access Panels, Unpowered Convenience
B = Hinged Access Panels, Powered Convenience
2
Intake / Exhaust Options
A = None
B = Temperature Economizer with Barometric Relief
F = Enthalpy Economizer with Barometric Relief
U = Temperature Ultra Low Leak Economizer
with Barometric Relief
W = Enthalpy Ultra Low Leak Economizer
with Barometric Relief
Base Unit Controls
3 = SystemVu™ Controller
8 = Electromechanical Controls — can be used with POL224
EconomizerONE (With Fault Detection and Diagnostic)
Design Revision
- = Factory Design Revision
Voltage
1 = 575-3-60
5 = 208/230-3-60
6 = 460-3-60
60
A
0
Packaging & Seismic Compliance
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
N = Phase Monitor/Protection
Q = Phase Monitor/Protection
and Non-Fused Disconnect
R = Phase Monitor/Protection
and Thru-The-Base Connections
T = Phase Monitor/Protection with Non-Fused
Disconnect and Thru-The-Base Connections
1 = High SCCR (Short Circuit Current Rating)
Protection
2 = High SCCR Protection and Thru-The-Base
Connections
Unpowered Convenience Outlet
Powered Convenience Outlet
High Efficiency Filter Track
High Efficiency Filter Track
Efficiency Filter Track
Outlet and 4" MERV 13 High Efficiency Filter Track
Outlet and 4" MERV 13 High Efficiency Filter Track

Advertisement

Table of Contents
loading

Table of Contents