Connecting Water; Figure 3 - Nirvana B50 Installation Instructions Manual

Swimming pool heat pump unit
Hide thumbs Also See for B50:
Table of Contents

Advertisement

NIRVANA heat pumps must never be installed in an enclosed area such as a garage or shed. 
 
5.2 
CONNECT
ING WATER 
 
Connect  the 
water  line  from  the  swimming  pool  filter  to  the  «WATER  IN»  connector located  at  the  base  of  the 
1.
heat pump. 
Connect the water line returning to the swimming pool to the «WATER OUT» connector located at
2.
heat pump. 
Once all connections are made, turn the filter pump on to check water circulation and ensure that all connections 
3.
are watertight. The flow rate must be at least 208 litters/minute (55 U.S. GPM / 46 imperial GPM). 
A circulatio
n pump that reaches top performance with a flow of 208 litters/minute (55 U.S. GPM / 46 imperial GPM) 
must be installed to ensure you achieve sufficient water flow (minimum of 1.5 HP circulation pump is recommended).
 
FIGURE 3 
 
 
 
Connecting  your  heat  pump  to  your  pool's  water  line  is  a  simple  operation  that  can  be  done 
te
chnician. All you will need is flexible pipe, 1½" in diameter inside, and stainless steel clamps. 
 
It is also possible to use rigid PVC pipe but this method
 
WARNING 
 is 
generally more difficult and expensive. 
8
 the base of the 
 
by  you  or  a  qualified 
 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E60E95E75E116C­110C100 ... Show all