NIRVANA heat pumps must never be installed in an enclosed area such as a garage or shed.
5.2
CONNECT
ING WATER
Connect the
water line from the swimming pool filter to the «WATER IN» connector located at the base of the
1.
heat pump.
Connect the water line returning to the swimming pool to the «WATER OUT» connector located at
2.
heat pump.
Once all connections are made, turn the filter pump on to check water circulation and ensure that all connections
3.
are watertight. The flow rate must be at least 208 litters/minute (55 U.S. GPM / 46 imperial GPM).
A circulatio
n pump that reaches top performance with a flow of 208 litters/minute (55 U.S. GPM / 46 imperial GPM)
must be installed to ensure you achieve sufficient water flow (minimum of 1.5 HP circulation pump is recommended).
FIGURE 3
Connecting your heat pump to your pool's water line is a simple operation that can be done
te
chnician. All you will need is flexible pipe, 1½" in diameter inside, and stainless steel clamps.
It is also possible to use rigid PVC pipe but this method
WARNING
is
generally more difficult and expensive.
8
the base of the
by you or a qualified