WATER PRESSURE GAUGE  
 
The pipes connecting the different water filtration and heating components often include a large number of bypass 
and/or service valves, sometimes leading to inadequate or no water pressure. 
 
FIGURE 5 
5.5 
OPERATION OF THE HEAT PUMP
 
1
.
The swimming pool water pump must always be ON when the heat pump is in operation. If the swimming pool 
water pump is equipped with a timer, make sure that the heat pump's operating time is synchronized with the 
water pump's operating time, with priority to the pool heater. The pool heater may have to operate for longer 
periods than the water pump of the swimming pool. 
 
2
.
The  heat  pump  may  occasionally  generate  condensation  in  the  form  of  mist  when  the  relative  humidity  is  at 
higher levels. 
 
3
.
The condensation formed on the heat collector may cause dripping under the heat pump. 
 
4.
The se of a bypass valve system is always recommended to facilitate maintenance. 
 u
 
5.
Wh   starting  the  heat  pump,  the  fan  will  start  immediately  but  the  compressor  will  take  between  3  and  5 
en
minutes to start up. 
  
5.6 
ELECTRICAL CONNECTION 
 
S
ome of our models come with a junction box located at the base of the unit, refer to Figure 6 A. 
Most of our models have two outputs (one on each side at the bottom of the unit) to choose whic
the power cord. Simply remove one of the two caps. To connect to within the unit, refer to Figure 6 B. 
 
Note: You will find the heat pump's electric plan at the end of this manual and on the inside of the electrical casing 
of your unit.  This one must be connected to a food of 240v single‐phase current. 
 
 
 
 
 
 
 
 
The pressure gauge should read between 5 and 15 Psi. 
 
A high water pressure reading on the filter gauge does not necessarily mean 
that enough water pressure is reaching the heat pump. 
  
A good pressure should be held in the green section.  If the pressure is in 
the yellow section, you have to do a backwash.  If the pressure is in red 
section, you have a problem with the out water of the machine.  It might 
be a bad position of the bypass valve. 
 
 
 
 
 