9.3
SELECTION OF MODE (MODEL C95 ONLY)
To keep the unit in the HEAT MODE ONLY: Press the "SELECT" until "ACH" appears and press the arrow keys until
"HEA" appears. Thereafter it remains only to choose the desired temperature. This feature allows you to control the
minimum level desired. The unit will heat the water until the desired temperature is reached.
To keep the unit in COOLING MODE ONLY: Press the "SELECT" until "ACH" appears and press the arrow keys until
"COL" appears. Thereafter it remains only to choose the desired temperature. This feature allows you to control the
desired maximum degree. The unit will cool the water until the desired temperature is reached.
To put the unit in AUTO MODE: Press the button "SELECT" until "ACH" appears and press the arrow keys until "AU"
appears. Thereafter it remains only to choose the desired temperature. This function keeps water at desired
temperature. In other words, it will heat or cool water until the water temperature reaches the degree selected.
BACKWASH OPERATIONS
1. Carry out the backwash procedure as follows:
2. Turn OFF the power to the pump (with power supply or (FIL = OFF, POL = OFF and SPA OFF)).
3. Prepare the system for backwash and power ON the pump (with power supply or (FIL = ON)).
4. The circulating pump will go ON and the controller will not check for 5 minutes if water flow is present at the
flow switch.
5. You will have 5 minutes of uninterrupted water flow to do the backwash.
6. Stop the circulating pump (use the power supply or FIL=OFF).
Normally, when the circulating pump is required for this operation and there is no water flow detected at the control,
the pump will automatically turn OFF. This procedure will give a 5 minute period of uninterrupted water flow before
the circulating pump turns OFF.
CHANGING THE DISPLAY FROM F° TO C°
Factory defaults are in F°.
Press and hold down the SET key until the message POL appears.
Press the SET key until F_C is displayed.
Press the ↑ key to select °F or press the ↓ key to select °C.
RESETTING THE DISPLAY
If a flashing PLE or CSE error message is displayed, hold down the SET key until the error message is no longer
displayed (approx. 4 seconds). The control will be reset to the factory default.
Reprogram all the settings.
DE‐ICING OPERATION
During the evaporator coil de‐icing cycle, FS will be displayed to indicate that the unit is de‐icing. During this time, the
fan is on and the compressor is not in operation
19