General - Sony KDS-50A2000 Service Manual

Sxrd projection tv
Hide thumbs Also See for KDS-50A2000:
Table of Contents

Advertisement

Other Information

General

Problem
How to reset the TV to factory
settings
How to restore Picture settings
to factory settings
How to restore Sound settings
to factory settings
Cannot cycle through the other
video equipment connected to
the TV
Cannot operate the setting
Lost password
TIMER LED on front panel is
lit
POWER LED blinks in red
LAMP LED blinks in red
The replacement lamp does not
light up
Digital cable box does not work ❏
TV cabinet creaks
A slight creaking noise occurs
from the bottom part of the TV
The cooling fan is loud
"High Temperature Warning"
message appears
The TV does not turn on
58
Possible Remedies
Turn on the TV. While holding down the V button on the remote control, press the
POWER button on the TV. Release the POWER button then release the V button.
The TV will turn itself off, then back on again with Initial Setup.
WARNING: This operation will clear all of your customized settings including
Parental Lock setting.
Select Reset setting option while in the Picture setting (see page 34).
Select Reset setting option while in the Sound setting (see page 37).
Be sure the Label Video Inputs option is not set to Skip (see page 45).
If a setting option appears in gray, this indicates that the setting option is not
available.
On the password screen, enter the following master password: 4357. The master
password clears your previous password; it cannot be used to temporarily unblock
channels.
When lit, indicates that the timer is set (see page 46). When the timer is set, this
LED will remain lit even when the TV is turned off.
If the LED blinks three times, the lamp door or the lamp might not be securely
attached (see page 51). The LED blinks two times if there is an abnormal rise in
temperature inside the TV when any ventilation openings are blocked.
Replace the lamp (see page 51).
The lamp door or the lamp might not be securely attached. Repeat the steps on
page 51 to ensure that they are both installed securely.
If you are connecting a VCR and digital cable box using a splitter, as described on
page 17, you must use a special bi-directional splitter that is designed to work
with your digital cable box. Contact your cable provider for details.
When the TV is in use, there is a natural rise in temperature, causing the cabinet to
expand or contract and may be accompanied by a slight creaking noise. This is not
a malfunction.
Advanced Iris applies a mechanical iris system. When Advanced Iris is set, a
natural creaking noise occurs due to the basic structure of the optical unit. The
creaking sound is an inherent nature of this system and is not a defect.
If the TV is used at high altitudes and Cooling Mode is set to High, the cooling
fan runs faster and its sound becomes louder. If the TV is not used at high
altitudes, set Cooling Mode to Normal (see page 47).
Make sure to remove dust from the ventilation slots on the rear and both sides of
the TV. In addition, make sure that there are no obstacles in front of the ventilation
slots. If the message still appears after the dust or obstacles are removed, the TV
may need servicing. Call your local Sony Service Center.
The TV cools down its projection lamp when the power is turned off. It takes up to
two minutes for the picture to come back after the TV is turned on again. Wait for
a while until the picture comes back.

Hide quick links: