Control
■ Table of Remote Control Warnings
Defective remote control reception
Remote control detects
an abnormal signal
Defective remote control transmission
from an indoor unit.
Defective reception by indoor unit from remote control (concentrated)
Duplicated indoor unit address setting
Defective setting
Several parent remote controls settings
Defective reception by an indoor board from the signal output board
Start of automatic addressing prohibited, due to being in automatic addressing
Defective transmission from an indoor unit to the remote control
Defective group control wiring communications
Defective reception by an indoor unit from an outdoor unit
Defective transmission from an indoor unit to an outdoor unit
Defective reception by an outdoor unit from an indoor unit
Defective transmission from an outdoor unit to an indoor unit
Too few units
Automatic
address warning
Abnormal outdoor control board
Abnormal outdoor control board sensor
Abnormal transmission within a unit
Non-conformance of outdoor and indoor unit types (equipment apart from GHP connected)
Multiple parent devices set for group control
Duplication of
priority settings
Other than priority indoor units
on indoor unit
There is group control wiring to separate control indoor unit
Indoor unit capacity not set
Duplication of system (outdoor unit) address settings
Outdoor unit capacity not set
Defective setting of indoor unit type
Defective pairing of indoor unit (defective double duct pairing)
Defective gas type setting
Abnormality
in the indoor
unit sensor
system
Abnormality
in the outdoor
sensor system
Indoor nonvolatile memory (EEPROM) abnormality (*1)
Clock function (RTC) abnormality
Outdoor nonvolatile memory (EEPROM) abnormality
Detection item
Too many units
Priority indoor unit
Indoor heat exchanger inlet temperature sensor abnormality
Indoor heat exchanger interim temperature sensor abnormality
Indoor heat exchanger outlet temperature sensor abnormality
Indoor unit intake temperature sensor abnormality
Indoor unit blow-out temperature sensor abnormality
Compressor outlet temperature sensor abnormality
Outdoor heat exchanger inlet temperature sensor abnormality
Outdoor heat exchanger outlet temperature sensor abnormality
External air temperature sensor abnormality
Compressor inlet temperature sensor abnormality
Cooling water temperature sensor abnormality
Compressor inlet/outlet pressure sensor abnormality
Exhaust gas temperature sensor abnormality
Clutch coil temperature sensor abnormality
Warning
Wireless remote control
display
lamp display
E01
E02
E03
Operating
E08
E09
E11
Flashing
E12
E13
E18
E04
E05
E06
Operating
E07
E15
E16
E21
E22
E31
L02
Operating
L03
L05
L06
L07
Simultaneous flashing
L09
L04
Operating
L10
L13
L15
Simultaneous flashing
L21
F01
Operating
F02
F03
F10
Alternative flashing
F11
F04
F06
F07
Operating
F08
F12
F13
Alternative flashing
F16
F18
F20
Operating
F29
Simultaneous flashing
Operating
F30
F31
Simultaneous flashing
C - 7
3. List of Warnings
: Flashing
: Lit
: Off
Device
checked
Remote
control
Indoor
Timer
Preparing
unit
Remote
control
Indoor
unit
Outdoor
unit
Indoor
unit
Indoor
unit
Timer
Preparing
Outdoor
unit
Flashing
Indoor
unit
Timer
Preparing
Outdoor
unit
Indoor
unit
Timer
Preparing
Outdoor
unit
Lit
Timer
Preparing
Indoor
unit
Timer
Preparing
Outdoor
unit
Lit
Timer
Preparing
Indoor
unit
Timer
Preparing
Outdoor
unit
Lit