Sanyo SGP-E70J2GU2 User Manual page 10

Table of Contents

Advertisement

Outdoor Unit
Model
External dimensions (mm)
Hei
ght
W
idth
Dept
h
Weight (kg)
Performance (kW)
Cooling capacity
Heating capacity
(Standard)
Heating capacity
(low temperature)
Power supply
Electrical characteristics 50Hz
Cooling
(230V)
Heating
(230V)
Start up current (A)
Fuel consumption (kW) G/C
C ooling
Heating
(standard)
Heating
(low temperature)
Compressor
Cooling oil volume (L)
Crank case heater (W)
Notes
1. The cooling capacity and heating capacity described in the tables are the values when the unit operates under the test condition of JIS B 8627
Operating condition
Indoor air intake temperature
Outdoor air intake temperature
2. The value of cooling power consumption indicates the electrical power consumed during cooling overload operation when Indoor air intake
temperature is 32ºCDB/23ºCWB, and Outdoor air intake temperature is 43ºCDB.
3. The operating noise was measured at the position of 1.5 meter from the ground and 1 meter from the front of the unit. However, in an actual
installation there are various additional conditions, and normally the noise level is higher than the indicated value.
4. Under fuel consumption, G indicates 100% propane, with a calorific value of 37.78MJ/NM
5. The values shown in the table are for 50Hz.
6. The specification is subject to change without notice, due to improvements etc.
SGP-E90J2GU2
2,253
2,253
2,253
1,290
1,000(+106)
720
28.0
33.5
33.5
220 ~ 240V
Operating
2.9
current(A)
Power consumption
0.63
(kW)
Power factor (%)
93
Operating
3.2
current(A)
Power consumption
0.70
(kW)
Power factor (%)
94
25
22.6/25.9
24.7/28.3
27.2/32.5
2.7(HP-9)
20
Cooling
Heating(standard)
27ºCDB, 19ºCWB
20ºCDB
35ºCDB
7ºCDB, 1ºCWB
Engine
Displacement(L)
Rated output(kW)
Lubricating oil
Starter motor
Starter type
Engine cooling water
Quantity(L)
Concentration, freezing
temperature
Cooling water pump rated
output(W)
Refrigerant×Quantity(kg)
Air intake
Air outlet
Piping
Refrigerant gas tube
Refrigerant liquid tube
Fuel gas port
Exhaust gas drain port
diameter(mm)
Operating noise dB(A)
Blower
Blower type
Rated air volume(m
Rated output (kW)
Heater for drain filter (W)
Heater for cooling water
Cooling water heater(W)
Paint color (Munsell code)
Heating(low temperature)
Less than 20ºCDB, 15ºCWB
2ºCDB, 1ºCWB
3
+5%, and C indicates other gas.
B - 5
2. Specification
1.274
7.5
Type
Sanyo Genuine GHP 10TH
Quantity
32
(L)
DC12V×0.8kW
AC/DC conversion type DC
starter
23
50V/V%, -35
160
HFC[R407C]×10
Front and rear
Top
28.58(brazed)
12.7(brazed)
R3/4(male screw)
27 rubber hose
56
Propeller fan×1
3
/min)
150
0.45
20
250
Silky shade (1Y8.5/0.5)
ºC