Pnp Name (Plug And Play) Procedure - Ricoh G165 Service Manual

G165; g166; g167; g181; g183; g184
Hide thumbs Also See for G165:
Table of Contents

Advertisement

Rev. 02/03/2010
17. Select "Registration", and then adjust the registration for each direction (vertical and
horizontal direction) and tray if necessary.
18. Select "2nd Transfer Fuser Temp" and then adjust the transfer roller bias and the
temperature reduction of the fusing unit for each paper type and for the front and back
sides. The default settings for normal operation are all '0'.
19. Exit "Engine Maintenance."

PnP Name (Plug and Play) Procedure

Set the PnP name as follows when replacing the EEPROM of the MF version.
0xAB
A indicates the brand. B indicates the model.
A: Brand
Brand
0
Name
Not used
B: Model
Brand
Model 0x00 0x11
Aficio
not
Name
SP
used
C220S
Brand ID: 0x01 (default)
This ID is not related to the PnP Brand name. Do not change the setting; otherwise, a
malfunction may occur.
Maintenance ID: 0x00 (default)
Do not change the setting; otherwise, a malfunction may occur.
LSU Adjustment
Input the data using the number keys. The cursor can be moved to the right or the left with
the Down arrow or the Up arrow keys. You can change the alphanumeric characters by
repeatedly pressing the number keys (like a mobile phone). (Example: 2
There is no "back space" function. If you input incorrect data, you have to delete all the data
input by pressing the Clear/Stop key. Then, input the LSU data again.
SM
1
2
3
RICOH Gestetner Not used LANIER
Gestetner, LANIER, NRG,
Ricoh: 1
Savin: A= 2, 4, 5, or 6
0x12
0x13
0xA4 0xA5
Aficio
Aficio
SP
SP
SP
C220S
C221SF
C222SF
3-63
Electrical Components
4
5
NRG
0xA6
0x77
SP
SP
C220SF C221SF C222SF
C221SF
C222SF
G165/G166/G167/G181/G183/G184
6
7
Savin
Generic
Generic:7
0x78
0x79
a
b
c)

Advertisement

Table of Contents
loading

This manual is also suitable for:

G166G184G167G181G183

Table of Contents