Installation - Vanguard VGL850N Owner's Operation And Installation Manual

B-vent decorative gas fireplace
Table of Contents

Advertisement

VENTED TYPE DECORATIVE APPLIANCE

INSTALLATION

WALL SWITCH
INSTALLATION (VGL850N/P)
The installation of a wall switch allows you
to activate the gas control valve without the
normal household electricity since the valve
operates on millivolt current supplied by the
heat generated by the thermopile
1. Remove the control access door panel
(see Figure 1, page 2).
2. Connect the 18 GA. wires (Provided
with wall switch kit) from the gas con-
trol valve to the wall switch as shown
in Figure 12.
ON
OFF
IN
OUT
Figure 12 - Wall Switch Wiring Diagram
Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL)
105 C (25 ft. length MAXIMUM) or equivalent.
VGL850 Series
®
Note: If any of the original wire from the
unit control must be replaced, use the same
type or a higher rated wire (25 ft. maximum
length).
WARNING: Do not wire re-
mote wall switch to main power
supply (Standard 120v household
current).
Route Millivolt Wires
To
(Supplied) Through Gas
Thermopile
Line Conduit Sleeve
OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
(GHRC SERIES)
INSTALLATION
Note: If using optional wireless hand-held
remote control, the wall switch is no longer
operational.
Installing Receiver
1.
2.
Wall Switch
(Supplied)
3.
4.
5.
6.
7.
8.
(Back View)
Figure 13 - Installing Remote Receiver
(Shown from Rear of Mounting Bracket)
Battery
Clip
Terminal
Wires
Figure 14 - Installing Battery in Receiver
8
Remove access panel from lower front
face of firebox. Lift straight up on ac-
cess panel until it stops. Pull bottom of
access panel forward, then down.
Disconnect wall switch wires from TH
and TH/TP terminals on control valve
(see Figure 12).
Install remote receiver unit onto mount-
ing bracket using the two plastic mount-
ing clips (see Figure 13).
Connect wires to control valve. Con-
nect white wire to terminal TH. Con-
nect red wire to terminal TH/TP.
Locate the battery clip mounted on the
back of the receiver (see Figure 14).
Slide 9-volt battery (not included)
through the clip. Note: Only use alka-
line battery.
Attach the terminal wires to the battery
(see Figure 14).
Replace access panel. Place top of ac-
cess panel into opening and slide up.
Push bottom of access panel in and
slide down to install.
Receiver
9-Volt Battery
Plastic
Mounting
Clips
Mounting
Bracket
Receiver
105705

Hide quick links: