Element Test - Continuity - State Water Heaters RESIDENTIAL ELECTRIC WATER HEATER Service Handbook

Hide thumbs Also See for RESIDENTIAL ELECTRIC WATER HEATER:
Table of Contents

Advertisement

OHMS Resistance Check**
Disconnect wires from the element terminals.
NOTE: OHM readings may vary by up to
7.5% depending on the meter and the
element.
Always check meter for proper
operation by touching probe ends together.
Test Conditions:
This test uses the multi-meter's battery as the
electrical supply.
Procedures:
Power to the water heater is "OFF".
Multi-meter set to OHMS scale testing.
Black lead "Common" port.
Red lead in "Ω" or "OHMS" port.
Dial indicator set to scale above expected indication.
Note: Volts divided by Amps = OHMS
÷
18.75 Amps = 12.8 OHMS
Example: 240V.
Continuity Check**
Same as above but with meter set to continuity scale.
If the meter has an audible indicator, listen for sound..
Test probe on each terminal of an element
Rated
Voltage
600
120
23.2
208
72.1
240
92.8
277
128
Rated
Voltage
3000
120
4.64
208
14.4
240
18.6
277
25.6
480
76.8
** The above tests can also be conducted with the element removed from the tank.
--------------------------------------------------------------------------------------------------------------------------------------------
Technical Training Department
Ashland City, Tennessee ©2004
RESIDENTIAL ELECTRIC WATER HEATER
SERVICE HANDBOOK
ELEMENT TEST – RESISTANCE/CONTINUITY
Resistance of Element in Ohms (± 7.5%)
Rated Wattage
750
1000
18.6
13.9
57.7
43.3
74.3
55.7
102
76.7
3500
4000
12.4
10.8
15.9
13.9
21.9
19.2
65.7
57.5
8 of 36
Element
1250
1500
11.1
9.28
34.6
28.8
44.6
37.1
61.4
51.2
Rated Wattage
4500
5000
9.61
8.65
12.8
11.1
17.1
15.3
51.1
45.7
Residential Electric Svc Handbook
12.8
2000
2500
6.96
5.57
21.6
17.3
27.8
22.3
38.4
30.7
5500
6000
7.85*
7.2
10.1*
9.28
14.0
12.8
41.8
38.4
STC082