Sollae Systems CSW-H80 User Manual

Sollae Systems CSW-H80 User Manual

Serial to wlan converter
Hide thumbs Also See for CSW-H80:
Table of Contents

Advertisement

Quick Links

Serial to WLAN Converter
CSW-H80 User's Manual
Version 1.9
2010-08-18
Sollae Systems Co., Ltd.
http://www.sollae.co.kr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSW-H80 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sollae Systems CSW-H80

  • Page 1 Serial to WLAN Converter CSW-H80 User’s Manual Version 1.9 2010-08-18 Sollae Systems Co., Ltd. http://www.sollae.co.kr...
  • Page 2 CSW-H80 User’s Manual Ver. 1.9 To all residents of the European Union Important environmental information about this product This symbol on this unit or the package indicates that disposal of this unit after its lifecycle could harm the environment. Do not dispose of the unit as unsorted municipal waste;...
  • Page 3: Table Of Contents

    CSW-H80 User’s Manual Ver. 1.9 Contents Overview ..........................- 5 - 1.1 Overview ................................- 5 - 1.2 Application Examples ............................- 5 - 1.3 Components ................................. - 7 - 1.4 Specification ................................. - 8 - 1.4.1 Hardware ..............................- 8 - 1.4.2 Software ................................
  • Page 4 CSW-H80 User’s Manual Ver. 1.9 Operation Modes ........................ - 27 - 4.1 What is the Operation Mode? ........................- 27 - 4.2 How to entering each mode ........................- 27 - 4.3 Comparison with each mode ........................- 28 - 4.4 Normal Mode ..............................
  • Page 5 CSW-H80 User’s Manual Ver. 1.9 7.1.4 Using WPA and WPA2 ........................- 54 - 7.2 TELNET COM port Control Option (RFC 2217) ................. - 55 - Self Test in Trouble ......................- 56 - 8.1 Searching problem with ezManager ...................... - 56 - 8.2 Connection Problem over TCP/IP ......................
  • Page 6: Overview

    The serial communication is quite simple to implement but has weaknesses like short distance and hard maintenance. CSW-H80 lets the serial devices connect to the Internet via wireless LAN (IEEE802.11b/g). To communicate on the Internet, devices should use TCP/IP protocol, so CSW-H80 processes the converting serial data to TCP/IP.
  • Page 7 CSW-H80 User’s Manual Ver. 1.9 INTERNET connection with a xDSL/cable modem  Fig 1-3 INTERNET connection with a xDSL/cable modem Infrastructure network with an AP  Fig 1-4 Infrastructure network with an AP - 6 - Sollae Systems Co., Ltd.
  • Page 8: Components

    CSW-H80 User’s Manual Ver. 1.9 Ad-hoc network without an AP  Fig 1-5 Ad-hoc network without an AP 1.3 Components CSW-H80’s body  Omni-directional dipole antenna  CD including utilities and documents (Option)  5V Power Adapter (Option)  RS232 cable for PC connection (Option) ...
  • Page 9: Specification

    2412MHz ~ 2472MHz (Ch. 1 ~ 13) RSSI 20dBm Temperature Operating: 0 ~ 55℃ / Storage: -40 ~ 85℃ Certification MIC: SLS-CSW-H80 (A) / CE: G107095X RoHS RoHS Compliant 1.4.2 Software TCP, UDP, IP, ICMP, ARP, DHCP, PPPoE, DNS lookup, DDNS, Protocol...
  • Page 10: Interface

    CSW-H80 User’s Manual Ver. 1.9 1.5 Interface 1.5.1 Layout 1.5.1 Wireless LAN Interface CSW-H80 embeds IEEE802.11b/g function which is interfaced an SMA female jack. An Omni-directional 2dBi antenna is also included in the package. - 9 - Sollae Systems Co., Ltd.
  • Page 11: Serial Interface

    And there is a Function button on the right side. And 5 LED indicators are in the CSW-H80. 1.5.3 Power DC5V is used for CSW-H80 and the specification is below: Fig 1-8 power connector - 10 - Sollae Systems Co., Ltd.
  • Page 12: Etc

    CSW-H80 User’s Manual Ver. 1.9 1.6 ETC 1.6.1 LED indicators There are 5 LED indicators on the CSW-H80. The followings are the operations of each LED indicators. Mode Name Color Status Description Common Supplying the power Yellow Blinks Receiving data from the WLAN...
  • Page 13: Installation And Test

    CSW-H80 User’s Manual Ver. 1.9 Installation and Test 2.1 Fundamentals of wireless LAN CSW-H80 supports IEEE802.11b/g. The IEEE802.11b and IEEE802.11g support 11Mbps and 54Mbps transmission rate respectively. There are two types of wireless LAN networks – infrastructure and ad-hoc. 2.1.1 Infrastructure Mode ...
  • Page 14: Basic Requisites

    CSW-H80 User’s Manual Ver. 1.9 Ad-hoc Mode  Wireless stations communicate each other without the AP. So user can make a system more simply. It is proper if there’s no wired LAN requirement and it is a small network. Some people call it peer-to-peer mode.
  • Page 15 Standard (AES), it is the WPA 2 that adopts the using the method. WPA 2 has also both Enterprise and PSK mode. CSW-H80 supports WPA 2-PSK (AES). CSW-H80 supports WEP, WPA-PSK (TKIP) and WPA2-PSK (AES) as security protocols.  - 14 - Sollae Systems Co., Ltd.
  • Page 16: Installation

    CSW-H80 User’s Manual Ver. 1.9 2.2 Installation Before testing H80, users should connect the serial port of CSW-H80 to a PC. And an Access Point (AP) is needed to connect the H80 to the wireless LAN (Recommended). Or, use wireless LAN card on your PC and make a network between the devices.
  • Page 17: Setting Network Aera

    PC to the network. 2.2.2 Setting Network Aera This step is for setting both CSW-H80 and your PC to be located the same network. If only they are, the TCP connection between them can be established. Setting of the PC ...
  • Page 18 Windows, and this is comfortable to use because it doesn’t need installation. First, search your CSW-H80 via network. All the values of parameters are set the default values in the factory. To apply it to your system, proper values should be set via ezManager.
  • Page 19: Simple Test

     Fig 2-4 settings for TCP connection ① Select [TCP Client] ② Input correct IP address and port number of CSW-H80 ③ Clink the [Connect] button. (In case of TCP Server, it will be [Listen] button) Opening RS232 Port ...
  • Page 20 CSW-H80 User’s Manual Ver. 1.9 Confirm the TCP Connection and COM port status  Fig 2-6 TCP Connected message ⑦ Check the message if the TCP connection is established Fig 2-7 COM Port open message ⑧ Check the message if the COM port has been opened - 19 - Sollae Systems Co., Ltd.
  • Page 21 CSW-H80 User’s Manual Ver. 1.9 Data transmission test  Fig 2-8 successful data transmission ⑨ Click the [Send data] on the LAN part ⑩ Check the data have been shown from the step ⑨ Fig 2-9 LAN → RS232 ⑪ Press the [Send data] on the RS232 part ⑫...
  • Page 22: Configuration

    3.1.1 Configuration via WLAN Checklists  Make sure the WLAN connection between your PC and CSW-H80. If they are the same network, [MAC Address search] button can be used. If they aren’t, only [IP Address search] is allowed to use.
  • Page 23: Configuration Via Serial

    Make sure the connection between your PC and CSW-H80 using RS232 cross cable. To use this, CSW-H80 has to be operating in the [Serial Configuration] mode. By pressing the ISP button shortly (less than 1 second), you can enter the mode. After this, read the setting via [Serial] tab on ezManager.
  • Page 24: At Command

     Make sure the connection between your PC and CSW-H80 using RS232 cross cable. To use this, CSW-H80 has to be set to [AT command] mode as its communication mode. This can be configured by ezManager. Fig 3-5 setting the communication mode to the AT command Procedures ...
  • Page 25: Assigning An Ip Address Automatically

    3.3 Assigning an IP address automatically 3.3.1 Obtain an IP automatically (DHCP) In the network environment composing DHCP server, settings related to CSW-H80’s IP address, subnet mask, gateway, and name servers can be automatically designated using DHCP protocol. In order to do so, you must check [Obtain an IP Automatically (DHCP)] category on the ezManager.
  • Page 26: Obtain An Ip Automatically (Pppoe)

    PPPoE is used in most ADSL and VDSL networks. To use PPPoE function, PPPoE function should be enabled and PPPoE ID and PPPoE password should be configured. The local IP address of CSW-H80 is assigned automatically in PPPoE environment. In this case, you can set the address of DNS server manually or automatically.
  • Page 27: Notify Ip Change

    CSW-H80 User’s Manual Ver. 1.9 3.3.3 Notify IP Change CSW-H80 can be TCP server even though it assigned IP address automatically. Using [Notify IP Change] function, H80 sends its IP address with the host name to the designed server. There are 3 types- DDNS, TCP and UDP- for this service.
  • Page 28: Operation Modes

    CSW-H80 User’s Manual Ver. 1.9 Operation Modes 4.1 What is the Operation Mode? Each of three operation mode of CSW-H80 is defined for specific purpose, and those are followed. Normal mode  This mode is for normal data communication and has 4 different connection modes.
  • Page 29: Comparison With Each Mode

    CSW-H80 User’s Manual Ver. 1.9 4.3 Comparison with each mode Table 4-1 shows summaries with each mode Table 4-1 comparison with each mode Name Entering Serial port configured Normal Supply the power. value Serial Press the ISP button shortly between 10ms and 1s.
  • Page 30: Serial Configuration Mode

    [Read] button on the [Serial] tab of ezManager. 4.5.2 Revoking Serurity Options CSW-H80 offers restriction methods for security like filtering password or MAC and IP address. In the serial configuration mode, you can revoke all of these. When you forgot the password, enter this mode to solve the problem.
  • Page 31: Communication Modes

    Communication Modes 5.1 TCP Server In this mode, CSW-H80 functions as a TCP server. CSW-H80 listens to a TCP connection from remote host. Once a host tries to connect to CSW-H80, it responses that request. After the connection is established, CSW-H80 converts the raw data from the serial port to TCP/IP data and sends them to the network and vice versa.
  • Page 32: Examples

    CSW-H80 User’s Manual Ver. 1.9 5.1.2 Examples A situation that [Event Byte] is set to 0.  Fig 5-1 time chart for a situation that [Event Byte] is set to zero Table 5-2 states of each point Points States H80 is listening to connection requests ①...
  • Page 33 CSW-H80 User’s Manual Ver. 1.9 A situation that [Event Byte] is set to 1.  Fig 5-2 time chart for a situation that [Event Byte] is set to 1 Table 5-3 states of each point Points States H80 is listening to connection requests ①...
  • Page 34 CSW-H80 User’s Manual Ver. 1.9 A situation that [Timeout] is set to 5.  Fig 5-3 time chart for a situation that [Timeout] is set to 5 Table 5-4 states of each point Points States Data communication on both sides ①...
  • Page 35: Tcp Client

    CSW-H80 tries to terminate established TCP connection. TCP Server  This check option is enable the TCP server / client mode. In this mode, CSW-H80 can be operated as a TCP server or client without changing its setting. DNS IP Address ...
  • Page 36: Examples

    CSW-H80 User’s Manual Ver. 1.9 5.2.2 Examples A situation that [Event Byte] is set to 0.  Fig 5-4 time chart for a situation that [Event Byte] is set to 0 Table 5-7 states of each point Points States Before the power is supplied ①...
  • Page 37 The connection has been established The “1234567” is transmitted to the remote host As you can see in the figure 5-5, CSW-H80 sends request segment right after the serial data had been 5 bytes. Even though those are come before the connection is established, the data “123”, “45”...
  • Page 38: At Command

    CSW-H80 User’s Manual Ver. 1.9 5.3 AT Command AT command is a mode which users control CSW-H80 with AT command like controlling modem. In this mode, active and passive TCP connections are available. And users are allowed to configure some environmental parameters with extended commands.
  • Page 39: Examples

    Processes of TCP connection ③ TCP connection has been established CSW-H80 sends “CONNECT” message to the serial port Most of the response messages from the serial port of CSW-H80 are omitted on above  figure. - 38 - Sollae Systems Co., Ltd.
  • Page 40 Set parameters in the AT command mode ① H80 sends a TCP connection request with the ATD command Processes of TCP connection ② TCP connection has been established CSW-H80 sends “CONNECT” message to the serial port - 39 - Sollae Systems Co., Ltd. http://www.sollae.co.kr...
  • Page 41 TCP connection has been terminated H80 sends “NO CARRIER” with disconnection CSW-H80 changes the mode to AT command, when receiving “+++” and sending “OK” message. In this state, the communication with remote host is not possible because H80 processes only AT command. Whenever you want to go back to online state (TCP connection), use “ATO”...
  • Page 42: Udp

    CSW-H80 User’s Manual Ver. 1.9 5.4 UDP UDP has no processes of connection. In this mode, data is sent in block units. Therefore, data that comes through CSW-H80’s serial port must be classified in block units to send it elsewhere. 5.4.1 Key parameters Event Byte ...
  • Page 43: Examples

    CSW-H80 User’s Manual Ver. 1.9 5.4.2 Examples Event Byte: 5 bytes / Data Frame: 1s (100 by 10ms)  Fig 5-9 time chart for event byte is 5 bytes and data frame is 1s Table 5-13 states of each point...
  • Page 44 ③ H80 updates host 2 to peer host H80 can communicate with remote host 2 The data “ABC”, “DE”, “FGH” are from the serial port of CSW-H80 in the “Fig 5-10 time  chart for [dynamic update of peer host].”...
  • Page 45: System Management

    6.1 Upgrading Firmware 6.1.1 Firmware Firmware is a type of software for operation of CSW-H80. If there are needs for adding function or fixing bugs, the firmware is modified and released. We recommend that users keep use the latest released firmware.
  • Page 46 CSW-H80 User’s Manual Ver. 1.9 Checking firmware file and Sending  Fig 6-2 sending firmware file ① Check if the name and path of the firmware file are correct ② Click the [Send] button ③ Request for reboot message will appear. After reboot, the program will send the file automatically.
  • Page 47: Status Monitoring

    CSW-H80 User’s Manual Ver. 1.9 6.2 Status Monitoring 6.2.1 Using TELNET Once the [TELNET] option is activated, users can remotely log in to CSW-H80. If a password is set, users should input the password. After then, messages from CSW-H80 appear like Fig 6-3.
  • Page 48 CSW-H80 User’s Manual Ver. 1.9 ST UPTIME  “ST UPTIME” command shows amount of time since H80 boots up. Fig 6-6 “ST UPTIME” command  “SD” command is used when users close a session. [OP1] means the number of COM port, and [OP2] means period of capturing and printing messages with 10ms unit.
  • Page 49: Using Ezmanager

    CSW-H80 User’s Manual Ver. 1.9 6.2.2 Using ezManager Status of CSW-H80 can be monitored by [Status] button on ezManager. By using the [Refresh Every 1 Second] option in the status window, the status is automatically updated in every second. Fig 6-8 status window of ezManager FIRMWARE VERSION ...
  • Page 50 Password  This text box is activated when CSW-H80 has a password. If users want to close TCP connection with right click of mouse on the session, this password has to be correctly filled.
  • Page 51: Debugging Message

    CSW-H80 User’s Manual Ver. 1.9 6.2.3 Debugging Message By using [Debugging] option, users can receive debugging messages from CSW-H80 on the network. Setting debugging option  Fig 6-9 setting debugging option ① Check the [Debugging Message] option ② Press the [Write] button ③...
  • Page 52 Fig 6-10 debugging message window ① Network Adapter ② Place for listing received debugging messages from CSW-H80 over the network ③ Auto update to display the latest captured file on the screen of ② ④ MAC address and serial port information of a selected product ⑤...
  • Page 53: Additional Functions

    The maximum length is 8 bytes of Alphabet or number. When you want to revoke all of these restrictions, operate CSW-H80 as the serial  configuration mode. In the mode, all restrictions are removable and communication with ezManager is revoked.
  • Page 54: Using Wep

    CSW-H80 User’s Manual Ver. 1.9 7.1.3 Using WEP Configuration of the Access Point  Set the parameters like authenticate method, key length and key index on the AP. Please refer to the AP’s manual for the configuration. Choosing Authentication and Encryption Methods.
  • Page 55: Using Wpa And Wpa2

    CSW-H80 User’s Manual Ver. 1.9 7.1.4 Using WPA and WPA2 Configuration of the Access Point  Set the related parameters on the AP first. Please refer to the AP’s manual for the configuration. Choosing Authentication and Encryption Methods.  Select the WPA on the panel.
  • Page 56: Telnet Com Port Control Option (Rfc 2217)

    CSW-H80 User’s Manual Ver. 1.9 7.2 TELNET COM port Control Option (RFC 2217) This option is for sending and receiving serial port states between two devices. Users can send and receive control signals like RTS/CTS when the states are changed.
  • Page 57: Self Test In Trouble

    CSW-H80 User’s Manual Ver. 1.9 Self Test in Trouble When users are in trouble with CSW-H80, make sure all the followed steps first. 8.1 Searching problem with ezManager Confirming types of configuration utility  CSW-H80 can be configured by ezManager.
  • Page 58: Connection Problem Over Tcp/Ip

    Address, DDNS option, and etc. Address, and etc. PING Test  Confirm the connection over the network by PING test. If the CSW-H80 doesn’t send any reply from the request, check the network environment. Firewall  In case the networks which need strong security, the access may be denied by their firewall.
  • Page 59: Data Communication Problem On The Serial

    CSW-H80 User’s Manual Ver. 1.9 8.3 Data Communication Problem on the Serial Connection of Pins  Check if the connection of each pin is right. Using cables, users choose the right type of cable which is suitable for the device. Transmit Data (TXD) pin should be connected with Receive Data (RXD) pin.
  • Page 60: Technical Support, Warranty, And Precaution

    Technical Support, Warranty, and Precaution 9.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: E-mail: support@eztcp.com...
  • Page 61: Precaution

    Do not use the product for a purpose that requires exceptional quality and  reliability relating to user’s injuries or accidents – aerospace, aviation, health care, nuclear power, transportation, and safety purposes. Sollae Systems is not responsible for any accident or damage occurring while using  the product. - 60 - Sollae Systems Co., Ltd.
  • Page 62: Revision History

    CSW-H80 User’s Manual Ver. 1.9 10 Revision History Date Version Comments Author 2008.12.09 ○ Initial Release ○ Add re-configuring the security function in the Serial 2009.01.08 Configuration Mode ○ Modify 7.1 Technical Support 2009.03.31 ○ Modify the table of 6.7.1 ○...

Table of Contents