Serial to WLAN Converter CSW-H80 User Manual Version 3.0 Sollae Systems Co., Ltd. http://www.ezTCP.com...
Page 2
CSW-H80 User Manual Ver. 3.0 This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment.
CSW-H80 is a converter that enables serial devices to support TCP/IP communication through wireless LAN. CSW-H80 carries out the converting process to help users get to the network using TCP/IP protocol.
CSW-H80 User Manual Ver. 3.0 1.3 Application Examples 1:1 network with a PC Figure 1-1 1:1 network with a PC 1:1 network with a PC through an AP Figure 1-2 1:1 network with a PC through an AP ...
CSW-H80 User Manual Ver. 3.0 1.4 Components CSW-H80’s body Omni-directional dipole antenna 5V power adapter (Optional) RS232 cable for PC connection (Optional) Bracket (Optional) Mounter (Optional) Patch antenna (Optional) DVD including utilities and documents (Optional) Components and options could be different by each local retail store in the world.
CSW-H80 User Manual Ver. 3.0 1.5 Specification 1.5.1 Hardware Input Voltage DC 5V (±10%) Power Current 300mA typical Dimension 93mm x 57mm x 24mm (without the antenna) Weight About 66g (without the antenna) RS232 – RTS/CTS Flow Control Serial (Baud Rate: 300bps ~ 230,400bps) Serial Port 2dBi external antenna (IEEE 802.11b/g)
CSW-H80 User Manual Ver. 3.0 1.6 Interface 1.6.1 Layout Figure 1-4 layout 1.6.2 Wireless LAN Interface CSW-H80 embeds wireless LAN module. An SMA Male jack is interfaced for an external antenna. - 9 - http://www.ezTCP.com...
CSW-H80 User Manual Ver. 3.0 1.6.3 Serial Interface There is an RS232 port. The port is interfaced with a 9 pin D-sub male connector. Figure 1-5 D-sub 9 pin male connector Pin Assignment Number Name Description level Dir. Etc.
CSW-H80 User Manual Ver. 3.0 1.6.4 Power DC5V is used for CSW-H80 and the specification is below: Figure 1-6 power connector 1.7 ETC. 1.7.1 LED indicators There are 5 LED indicators on the top panel. Operations of the indicators are as follows:...
1.7.2 Function button There is a function button on the side. With this button, you can change the operation mode of CSW-H80 to ISP or Serial Configuration mode. And the PC free options can be implemented by this button. Figure 1-7 function button - 12 - http://www.ezTCP.com...
Installation and Test 2.1 Fundamentals of wireless LAN CSW-H80 supports IEEE802.11b/g. IEEE 802.11 is also called wireless LAN and has two network topologies and those are Infrastructure and Ad-hoc mode. CSW-H80 also supports WEP, WPA-PSK (TKIP) and WPA2-PSK (AES) for security.
SSID to communicate in the network. In the case of infrastructure mode, you have to set the same SSID at an AP to CSW-H80. Otherwise, it will not communicate at all. The maximum length of this parameter is 31 bytes and the default is “sollae”.
(Wireless LAN standard) to replace the TKIP. CCMP uses Advanced Encryption Standard (AES) which is adopted by WPA2. WPA 2 has also both Enterprise and PSK mode. CSW-H80 supports WEP, WPA-PSK (TKIP) and WPA2-PSK (AES). - 15 - http://www.ezTCP.com...
The following instruction is written based on use of evaluation board for CSW-H80. Before testing CSW-H80, connect the serial port to your PC. And then, make wireless LAN link between the PC and CSW-H80 using an AP or wireless LAN adaptor.
Page 18
CSW-H80 User Manual Ver. 3.0 Configuring Wireless LAN Parameters On the [Wireless LAN] tab, set the same SSID and security options properly of the AP. Consult the manufacturer on how to set or figure the AP's value out if you have no idea about it.
CSW-H80 User Manual Ver. 3.0 2.2.2 Setting Network Aera This step is for setting both CSW-H80 and your PC to be located the same network. If only they are, the TCP connection between them can be established. Setting of the PC Add or change the IP address of the network adapter on your PC.
Page 20
Windows. This program is easy to use and doesn’t need installation. For setting CSW- H80, search your CSW-H80 via serial port first. All the values of parameters are set to the factory default. To apply CSW-H80 to your system, set proper values. Default values of major parameters are listed on the table below.
Connecting to the CSW-H80 via LAN Figure 2-7 settings for TCP connection ① Select [TCP Client] ② Input correct IP address and port number of CSW-H80 ③ Click the [Connect] button. (In case of TCP Server, it will be [Listen] button) Opening RS232 Port Figure 2-8 opening COM Port ④...
Page 22
CSW-H80 User Manual Ver. 3.0 Confirm the TCP Connection and COM port status Figure 2-9 TCP Connected message ⑦ Check the message if the TCP connection is established Figure 2-10 COM Port open message ⑧ Check the message if the COM port has been opened - 21 - http://www.ezTCP.com...
Page 23
CSW-H80 User Manual Ver. 3.0 Data transmission test Figure 2-11 successful data transmission ⑨ Click the [Send data] on the LAN part ⑩ Check the data from the step ⑨ has been shown Figure 2-12 LAN → RS232 ⑪ Press the [Send data] on the RS232 part ⑫...
Figure 3-1 procedures for configuration via Serial 3.1.2 Configuration via WLAN Checklists Make sure the WLAN connection between your PC and CSW-H80. If they are on the same network, [MAC Address search] can be used. Otherwise, only [IP Address search] is allowed to use.
Checklists Make sure the connection between your PC and CSW-H80 using RS232 cross cable. CSW-H80 has to be set to [AT command] mode as communication mode. This can be configured by ezManager. Figure 3-3 setting the communication mode to the AT command ...
Figure 4-1 how to entering each mode ① Reset (Power off) ② Reset or input “g 0” command ③ Reset (After transmitting firmware, CSW-H80 will be automatically reset) ④ Reset pushing the function button ⑤ Push the function button for a while (over 1 sec) ⑥...
RS232 115,200/N/8/1 RS232 Table 4-1 comparison with each mode 4.4 Normal mode 4.4.1 WLAN mode CSW-H80 supports three types of WLAN mode. WLAN mode Description Ad-hoc WLAN is composed to only stations without an AP Infrastructure WLAN is composed to an AP and clients...
CSW-H80 User Manual Ver. 3.0 4.4.2 Communication mode In normal mode, there are four types of connection to communicate with a remote host. Mode Description TCP Server Wait connection request from TCP clients (Passive Connection) TCP Client Send connection request to a TCP server (Active Connection)
4.5.2 Revoking Serurity Options CSW-H80 offers restriction for security like filtering with password or MAC and IP address. In the serial configuration mode, you can revoke all of these options. When you forget the password, enter this mode to change or delete it.
Communication Modes 5.1 TCP Server In this mode CSW-H80 listens to a request of TCP connection from remote hosts. Once a host tries connecting to CSW-H80, it accepts a connection. After the connection is established, CSW-H80 converts the raw data from the serial port to TCP/IP data and sends it to the network and vice versa.
Page 31
CSW-H80 User Manual Ver. 3.0 5.1.2 Examples A situation that [Event Byte] is set to 0. Figure 5-1 time chart Time States Before Three-way handshaking ① Remote host sends a connection request (SYN) segment. Processes of the connection ②...
Page 32
CSW-H80 User Manual Ver. 3.0 A situation that [Event Byte] is set to 1. Figure 5-2 time chart Time States Before Three-way handshaking ① Remote host sends connection request (SYN) segment. Processes of the connection ② The connection is established.
Page 33
① The last segment has been arrived at the H80 5 seconds are passed with no data communication ② CSW-H80 has sent disconnection request (FIN) to a remote host Processes of the disconnection ③ The connection has been terminated CSW-H80 is listening to connection requests...
Page 34
In this mode, CSW-H80 sends request segments to a TCP server with information of [Peer Address] and [Peer Port]. Once a host is listening, the connection will be established. After then, CSW-H80 converts the raw data from the serial port to TCP/IP data and sends them to the network and vice versa.
Page 35
A situation that [Event Byte] is set to 0. Figure 5-4 time chart Time States Before Three-way handshaking ① CSW-H80 sends a connection request segment. processes of TCP connection ② The connection is established. data communication on both sides Table 5-7 states of each point Look at the blue arrow above.
Page 36
The data “1234567” is transmitted to the remote host. Table 5-8 states of each point As you can see, CSW-H80 sends a request segment right after the size of the serial data becomes 1 bytes. Even though they arrive before finishing Three-way handshaking, the data “123”...
Page 37
CSW-H80 User Manual Ver. 3.0 5.3 AT Command AT command is a mode which users control CSW-H80 with AT command like controlling modem. In this mode, active and passive TCP connections are available. And users are allowed to configure some environmental parameters with extended commands.
Page 38
③ TCP connection has been established. CSW-H80 sends “CONNECT” message to the serial port. Table 5-10 states of each point Some of the response messages from the serial port of CSW-H80 are omitted on above figure. - 37 -...
Page 39
TCP Client - setting parameters and active connection Figure 5-7 time chart Time States configuring parameters with AT commands CSW-H80 has sent a TCP connection request with the ATD ① command. processes of TCP connection ② TCP connection has been established.
Page 40
CSW-H80 sends “NO CARRIER” with disconnection. Table 5-12 states of each point CSW-H80 changes to the command state, when receiving “+++”. In this state, the communication with remote host is not possible because CSW-H80 processes only AT commands. Whenever you want to go back to on-line state, just give “ATO” command.
Page 41
5.4 UDP UDP has no processes of connection. In this mode, data is sent by block unit. Therefore, data coming through CSW-H80’s serial port is classified by block units to send it elsewhere. Block Size(Byte) [Block Size(Byte)] is the size of a block in UDP mode. Its unit is byte. If the data in configured size of the [Block Size(Byte)] has come into the serial port, CSW-H80 sends them as one block to the network.
Page 42
Block Size: 5 bytes / Data Frame: 1s (100 by 10ms) Figure 5-9 time chart Time States CSW-H80 is receiving data from the serial port CSW-H80 has sent 5 bytes as one block based on the [Block ① Size]. Serial device is sending data “678”. ②...
Page 43
UDP data has arrived from Remote Host 2. Send UDP data to Remote Host 2. Table 5-15 states of each point The data “ABC”, “DE”, “FGH” are from the serial port of CSW-H80 in the above figure. - 42 -...
Page 44
6.1 Upgrading Firmware 6.1.1 Firmware Firmware is a type of software for operation of CSW-H80. If there are needs for adding function or fixing bugs, the firmware is modified and released. That's why we recommend that users keep using the latest released firmware.
Page 45
CSW-H80 User Manual Ver. 3.0 Checking firmware file and Sending Figure 6-2 sending firmware file ① Check if the name and path of the firmware file are correct ② Click the [Send] button ③ Request for reboot message will appear. After reboot, the program will send the file automatically.
Page 46
6.2 Status Monitoring 6.2.1 Using TELNET When the [TELNET] option is activated, you can remotely log in to CSW-H80. If a password is set, users should input the password. Starting with firmware version 2.0A, you can login by entering "sollae" without ...
Page 47
CSW-H80 User Manual Ver. 3.0 st uptime “st uptime” command shows amount of time since CSW-H80 boots up. Figure 6-6 “st uptime” command sd “sd” command is used when users close a session. [OP1] means the number of COM port, and [OP2] means period of capturing and printing messages with 10ms unit.
Page 48
CSW-H80 User Manual Ver. 3.0 6.2.2 Using ezManager Status of CSW-H80 can be monitored by [Status] button on ezManager. By using the [Refresh Every 1 Second] option in the status window, the status is automatically updated in every second. Figure 6-10 status window of ezManager ...
Page 49
Table 6-3 SERIAL STATUS ARP Table This part shows ARP table of CSW-H80. When TCP connection is established or UDP data communication is performed, the information of IP and MAC address is automatically registered in the table. This information lasts for 1 minute so when 50 seconds have passed, CSW-H80 starts broadcasting the ARP packet in every second.
Page 50
CSW-H80 User Manual Ver. 3.0 Password This text box is activated when CSW-H80 has a password. If you want to close TCP connection on [TCP/IP Connection] list, input the password first. Refresh Every 1 Second. If this option is checked, ezManager sends queries in every second.
Page 51
A password can be used for protecting CSW-H80 from TELNET login or changing environmental parameters by unqualified hosts. The maximum length is 8 bytes of Alphabet or number. When you want to revoke all of these restrictions, operate CSW-H80 as the serial configuration mode.
CSW-H80 User Manual Ver. 3.0 7.1.3 Using WEP Configuration of the Access Point Set the related parameters on the AP first. If you do not know how to set AP’s parameters, please refer to the manual or ask the manufacturer.
CSW-H80 User Manual Ver. 3.0 7.1.4 Using WPA Configuration of the Access Point Set the WPA-PSK or WPA2-PSK and related parameters on your AP first. If you do not know how to set AP’s parameters, please refer to the manual or ask the manufacturer.
[Send MAC Address] is a function to send MAC address to the remote host right after a connection. By using this function, a server can identify multiple devices with the information. 7.2.2 Debugging Message - ② By using [Debugging] option, users can receive debugging messages from CSW-H80 on the network. - 53 - http://www.ezTCP.com...
Page 55
Figure 7-7 debugging message window ① Network Adapter ② Place for listing received debugging messages from CSW-H80 over the network ③ Auto update to display the latest captured file on the screen of ② ④ MAC address and serial port information of a selected product ⑤...
CSW-H80 User Manual Ver. 3.0 7.2.3 Notify IP Change CSW-H80 can be a TCP server even though its IP address is automatically assigned. Using [Notify IP Change] function, CSW-H80 sends its IP address to the specific server. There are 3 types for this service; DDNS, TCP and UDP.
Refer to the [TELNET COM Port Control Option] document on our website for details. 7.3.2 Disable TCP Transmission Delay - ② If you use this option, CSW-H80 sends the data from the serial port to Ethernet as quickly as possible. - 56 - http://www.ezTCP.com...
CSW-H80 User Manual Ver. 3.0 7.3.3 Data Frame Interval - ③ Before sending data from the serial port to Ethernet, ezTCP gathers data in the buffer. If there is no data during the time configured in the [Data Frame Interval], ezTCP will send data to the network.
CSW-H80 User Manual Ver. 3.0 Checklist in Trouble When users are in trouble with CSW-H80, make sure all the followed steps first. 8.1 Searching problem with ezManager Confirming types of configuration utility CSW-H80 can be configured by ezManager. Stopping Firewall operation Firewalls of personal computer or network block broadcast packets.
Address, and etc. Table 8-1 major parameters related with TCP/IP PING Test Confirm the connection over the network by PING test. If the CSW-H80 doesn’t send any reply from the request, check the network environment. Firewall In case the networks which need strong security, the access may be denied by their firewall.
CSW-H80 User Manual Ver. 3.0 8.3 Data Communication Problem on the Serial Connection of Pins Check if the connection of each pin is right. Using cables, users choose the right type of cable which is suitable for the device. Transmit Data (TXD) pin should be connected with Receive Data (RXD) pin.
CSW-H80 User Manual Ver. 3.0 Related Materials 9.1 Documents You can find each document on our web site or included CD in your package. Datasheet CE certificate Declaration of RoHS Compliance Quick Start Guide 9.2 Applications for a Smart Phone ...
10 Technical Support and Warranty 10.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: E-mail: support@eztcp.com...
Do not use the product for a purpose that requires exceptional quality and reliability relating to user’s injuries or accidents – aerospace, aviation, health care, nuclear power, transportation, and safety purposes. Sollae Systems is not responsible for any accident or damage occurring while using the product. - 63 -...
Sollae Systems Co., Ltd. and its distributors entire liability and your exclusive remedy shall be Sollae Systems Co., Ltd. and its distributors option for the return of the price paid for, or repair, or replacement of the CSW-H80.
à pouvoir - 65 -sages- 65 -s le boîtier CSW-H80, même si Sollae Systems Co., Ltd. ou un de ses distributeurs a été informé de la possibilité de - 65 -sage dommages.
Page 67
- 66 -sages- 66 -s- 66 -- 66 -. Tous les boîtiers CSW-H80 sont testés avant - 66 - sages - 66 - s - 66 - - 66 - . Toute - 66 -sages- 66 -s- 66 -- 66 -i en dehors des - 66 -sages- 66 -s- 66 -- 66 -ions et limites indiquées dans cette documentation ainsi que les court-circuit, les chocs, les utilisations...
CSW-H80 User Manual Ver. 3.0 12 Revision History Date Version Comments Author 2008.12.09 ○ Initial Release ○ Add re-configuring the security function in the Serial 2009.01.08 Configuration Mode ○ Modify 7.1 Technical Support 2009.03.31 ○ Modify the table of 6.7.1 ○...
Page 69
CSW-H80 User Manual Ver. 3.0 ○ Change the domain name to ‘www.ezTCP.com’ Roy LEE ○ Update figures ○ Remove description about PPPoE and DHCP 2012.06.04 ○ Extend the warranty period to two years ○ Modify the descriptions of components ○ Correct some errors and expressions ○...
Need help?
Do you have a question about the CSW-H80 and is the answer not in the manual?
Questions and answers