Product Specifi c Information
A. Appliance Certifi cation
MODELS: ESCAPE-I30-F, ESCAPE-I30LP-F,
ESCAPE-I35-F, ESCAPE-I35LP-F
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2009 • CSA 2.33-2009
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Heat & Glo gas inserts are designed for installations into
solid fuel masonry or factory built fi replaces that have been
installed in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additional
outside air source is required.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory
trained professionals, or technicians supervised by
an NFI certifi ed professional (www.nfi certifi ed.org).
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
6
Heat & Glo • Escape-I35-F, Escape-I30-F Owner's Manual • 2347-981 Rev. G • 10/14
C. BTU Specifi cations
Models
(U.S. or Canada)
(0-2000 FT)
ESCAPE-I30-F
(NG)
CANADA
(2000-4500 FT)
(0-2000 FT)
ESCAPE-I30LP-F
(LP)
CANADA
(2000-4500 FT)
(0-2000 FT)
Escape-I35-F
(NG)
CANADA
(2000-4500 FT)
(0-2000 FT)
ESCAPE-I35LP-F
(LP)
CANADA
(2000-4500 FT)
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifi ce size.
Maximum
Minimum
Input
Input
BTU/h
BTU/h
US
36,000
17,000
33,250
16,750
US
36,000
19,000
31,000
15,500
US
40,000
20,000
37,000
19,250
US
38,000
19,000
35,000
17,000
Orifi ce
Size
(DMS)
33
34
50
51
31
32
49
50