HP XP48 Configuration Manual page 41

Storageworks disk array xp
Hide thumbs Also See for XP48:
Table of Contents

Advertisement

Error Condition
Physical volumes cannot be
created.
Logical volumes cannot be
created.
A file system is not mounted
after rebooting.
The disk array performs a
self reboot because the disk
array was busy or it logged a
panic message.
The disk array responds "Not
Ready" or the disk array has
displayed "Not Ready" and
timed out.
The host detects a parity
error.
The host hangs or devices are
declared and the host hangs.
Troubleshooting
Recommended Action
Verify that the disk array logical devices are correctly formatted.
Verify that the volume capacity for OPEN-x volumes is not greater
than the maximum capacity allowed. See the Device Emulations
Appendix.
Verify that the capacity of the volume group is not less than the total
capacity of the partitioned logical volume.
Verify that the host was restarted correctly.
Verify that the file system attributes are correct.
Reboot the host.
Contact HP.
Check the HBA and make sure it was installed properly.
Reboot the host.
Make sure there are no duplicate disk array TIDs and that disk array
TIDs do not conflict with any host TIDs.
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp128Xp512Xp1024Xp12000

Table of Contents