HP XP48 Configuration Manual page 33

Storageworks disk array xp
Hide thumbs Also See for XP48:
Table of Contents

Advertisement

Installation
----- please choose one (? for help, .. to quit this menu)-----
[exi]t
[d]ebug/
[b]adblock/
[exe]rcise/
Set the device parameters.fx> /label/set/param
fx/label/set/parameters: Error correction = (enabled)
fx/label/set/parameters: Data transfer on error = (enabled)
fx/label/set/parameters: Report recovered errors = (enabled)
fx/label/set/parameters: Delay for error recovery = (enabled)
fx/label/set/parameters: Err retry count = (0)
fx/label/set/parameters: Transfer of bad data blocks = (disabled)
fx/label/set/parameters: Auto bad block reallocation (write) = (enabled)
fx/label/set/parameters: Auto bad block reallocation (read) = (enabled)
fx/label/set/parameters: Read ahead caching = (enabled)
fx/label/set/parameters: Write buffering = (enabled)
fx/label/set/parameters: Drive disable prefetch = (0)
fx/label/set/parameters: Drive minimum prefetch = (0)
fx/label/set/parameters: Drive maximum prefetch = (0)
fx/label/set/parameters: Drive prefetch ceiling = (0)
Enter enable.fx/label/set/parameters: Enable CTQ = (disabled) enable
Enter desired queue depth.fx/label/set/parameters: CTQ depth = (2) 8
fx/label/set/parameters: Read buffer ratio = (0/256)
fx/label/set/parameters: Write buffer ratio = (0/256)
* * * * * W A R N I N G * * * * *
Enter yes.about to modify drive parameters on disk dksc(8,0,2)! ok? yes
----- please choose one (? for help, .. to quit this menu)-----
[exi]t
[d]ebug/
[b]adblock/
[exe]rcise/
Exit the fx utility.fx> exi
Enter yes.label info has changed for disk dksc(8,0,2). write out changes? (yes)
yes
[l]abel/
[a]uto
[r]epartition/
[l]abel/
[a]uto
[r]epartition/
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp128Xp512Xp1024Xp12000

Table of Contents