6. Operating Procedure
I.
Read the operation section in the manual carefully before proceeding onto the initial start-up.
II.
Start power source and allow for warm-up.
III.
Verify the compressor is disengaged.
IV.
Engage hydraulic system per company policy.
V.
Engage compressor.
7. Shutdown Procedure
I.
Disengage compressor circuit.
II.
Relieve system of stored air.
The following conditions should exist for maximum performance of the compressor. The truck should be as
close to level as possible when operating. Operation in ambient temperatures above 100°F (38°C) may
experience high temperature shutdown.
Installation & Operation
Operating Conditions
16