Download Print this page

Technical Data; Specifications - Siemens CHSL4010 Installation Manual

Large camera housing
Hide thumbs

Advertisement

Technical data

3
Technical data
3.1

Specifications

Nominal Voltage
Fuse Rating (Fuse F1)
Electrical Connections
Cable Entry
Heater
Environmental
Operating Temperature
Maximum internal dissipated power
Relative humidity
Weatherproof rating
Material
Finish
Internal Dimensions (L x W x H)
Usable Height with Wiper fitted
Weight
Suitable Pan and Tilt Units
Suitable Brackets
8
Siemens Building Technologies
Fire Safety & Security Products
CHSL4010:
110 – 230 V AC, 50/60 Hz
CHSL4011:
12 – 24 V AC, 50/60 Hz
CHSL4010:
2 A 250 V AC 5 x 20 Type (T), HBC
CHSL4011:
5 A 250 V AC 5 x 20 Type (T), HBC
Main supply connections via fused PCB mounted terminal blocks.
Use crimped ferrules when terminating cables.
6 way pillar terminal block available for user connections.
1 x 25 mm hole to accept conduit (fitted with blanking plug).
1 x 16 mm Cable Gland
(5 – 10 mm diameter cable range)
2 x 20 mm Cable Glands
(6 – 12 mm diameter cable range)
7 W nominal, 25 W max.
PTC resistor heating element, thermostatically controlled.
-20 to +60 °C (-20 to +40 °C when wiper kit fitted)
Ensure fitted equipment has suitable temperature range for the
application (e.g. maximum typical ambient operating temperature of
camera and lens. Ta = 40 °C).
50 W (25 W (including wiper motor) when wiper kit fitted)
Up to 95 % non-condensing
IP66, BS EN 60 529
Toughened Glass Window
Aluminium extrusions (Housing body / Sunshield)
Die cast aluminium (front and rear end caps)
Endcaps: Polyester powder coat, RAL7016 Grey
Housing Body: Polyester powder coat, RAL9006 White Aluminium
Sunshield: Polyester powder coat, RAL9006 White Aluminium
400 x 125 x 110 mm
88 mm
Including Sunshield: 6.0 Kg
Excluding Sunshield: 4.9 Kg
CDD2425, CDD2416-T, CDAP2316-T, CDAP2416-T
CHBS2815, CDBS4540 + CAHA1040
09.2008

Advertisement

loading

  Related Manuals for Siemens CHSL4010

This manual is also suitable for:

Chsl4011