Adjusting the Sunshield ................11 Accessing the inside of the Housing Enclosure........11 Mounting the Camera and Lens Assembly..........12 Mounting the Camera Housing Assembly ..........13 Connecting to the Power Supply.............14 Maintenance and service ..............16 Disposal ....................16 Siemens Building Technologies Fire Safety & Security Products 09.2008...
Risk of cable damage due to stress Use only cable types that are approved for the environmental requirements. The cable glands used must be appropriate for the cable diameter. Siemens Building Technologies Fire Safety & Security Products 09.2008...
There is a risk of minor to medium injuries or damage to property IMPORTANT Malfunctioning may result Meaning of the hazard symbols The nature of the hazard is indicated by icons. Warning of a hazard Siemens Building Technologies Fire Safety & Security Products 09.2008...
EU Directives EU Directives The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe Germany EU Directive 2004/108/EC on electromagnetic compatibility...
Usable Height with Wiper fitted 88 mm Weight Including Sunshield: 6.0 Kg Excluding Sunshield: 4.9 Kg Suitable Pan and Tilt Units CDD2425, CDD2416-T, CDAP2316-T, CDAP2416-T Suitable Brackets CHBS2815, CDBS4540 + CAHA1040 Siemens Building Technologies Fire Safety & Security Products 09.2008...
149 mm Key to Parts Fig. 2 Key to Parts Front End Cap Cable Anchor Housing Body Terminal Board Sunshield Camera Mounting Plate Rear End Cap Demister Assembly Cable Glands Window Siemens Building Technologies Fire Safety & Security Products 09.2008...
24 V AC Wiper Kit CAHL401X-WK Spare Wiper Arm Assembly CAHL4010-WU 230V AC Washer Unit CAHL4011-WU 24V AC Washer Unit CAPD1210-C230 12 V DC 500 mA PSU 230 V AC input Siemens Building Technologies Fire Safety & Security Products 09.2008...
To re-assemble carry out steps 1 to 4 in reverse, making sure the earth wire is reconnected. The screws which secure the housing to the rear cap should be retightened to a torque of 2 Nm. Fig. 4 Inside the housing enclosure Rear End Cap Siemens Building Technologies Fire Safety & Security Products 09.2008...
5.5 for details on connecting to the power supply. Use the cable anchors to clamp all cables. Once the camera installation and wiring is complete, close the housing as described in section 5.2. Fig. 5 Mounting the Camera and Lens Assembly Siemens Building Technologies Fire Safety & Security Products 09.2008...
Screw the mounting bracket to the base of the unit (A) (see Fig. 6). Secure the assembly following the bracket installation instructions. Fig. 6 Mounting the Camera Housing Assembly Siemens Building Technologies Fire Safety & Security Products 09.2008...
CAUTION building installation, protect the unit via a fuse or circuit breaker rated at 2 A for CHSL4010 110 – 230 V AC units and 5 A for CHSL4011 12 – 24 V AC units. NOTE Use only cable suitable for the application and that meets the standards required by the installation.
Page 15
Fuse F1 2 A 250 V AC 5x20 Type (T), HBC for T462 5 A 250 V AC 5x20 Type (T), HBC for T463 Heater Output (pre-wired and connected through fuse F1) Siemens Building Technologies Fire Safety & Security Products 09.2008...
Neither do they constitute or amend any earlier or existing commitment or legal relationship. All obligations on the part of Siemens result from the relevant purchase agreement which also contains the complete and solely valid warranty regulations. This installation guide neither extends nor restricts these contractual warranty regulations.