Download Print this page
First Alert FA215KP Installation Manual

First Alert FA215KP Installation Manual

Remote keypads

Advertisement

Quick Links

Keypad Features
Backlit Display
Dedicated Function Keys
Built-in Sounder
First Alert Pro Controls
FA110C*
FA120C*
FA142C*
FA148C*
FA162C*
FA1220CV**
FA1340C**
FA1600C/CA/CB**
FA2000C*
The FA560KP must be used to program the FA142C, FA148C, FA162C, FA1220CV, FA1340C, FA1600C/CA/CB, & FA2000C controls.
*
Use the non-addressable mode with these controls (set to address 31).
**
Use the addressable mode with these controls (addresses 00-30).
Notes
1. Permanent display backlighting is an option on some controls (see the control's instructions for details).
2. The FA560KP is required for certain advanced user functions (see the control's instructions for details).
3. Use the FA560KP with the red color insert (provided for fire installations) as required by local authority having jurisdiction
GENERAL INFORMATION
The FA215KP, FA260KP & FA560KP are addressable
Remote Keypads and are intended for use with the controls
listed in table above. Addresses are set via the keypad keys
(no DIP switches). See the table above for valid addresses.
The keys on the keypads are continuously backlit for
convenience except the FA215KP.
KEYPAD DISPLAYS AND LEDS
The keypads have the following features of the display:
Fixed
2-line
Model
Word
Alpha
Display
Display
FA215KP
X
FA260KP
X
FA560KP
The following table shows the LEDs and their functions:
LED
Function
Red
Lights when the system is armed in any mode
Green
Lights when the system is "ready" to be armed.
SPECIAL FUNCTION KEYS
The keypads also feature function keys, see table below.
These keys may be programmed for panic alarms or other
special functions such as macros. See the control's
instructions for details. The FA215KP uses the key pairs
only. Function keys must be held down for at least 2
seconds to activate an alarm; key pairs activate
immediately.
FA260KP/FA560KP
A ([1] & [*])
B ([*] & [#])
C ([3] & [#])
D
INSTALLATION GUIDE
FA215KP
Fixed-Word
NO
NO
Piezo
YES
YES
YES
YES
YES
YES
YES
NO
YES
2-digit
Custom Zone
Zone
Descriptors
Identifier
X
X
X
FA215KP
[1] & [*]
[*] & [#]
[3] & [#]
NONE
FA260KP
Fixed-Word
YES (See Note 1)
YES
Speaker
YES
YES
YES
YES
YES
YES
YES
NO
YES
WIRING AND INSTALLATION
The keypads can be surface mounted directly to a drywall, or to
a single- or double-gang electrical box.
1.
Remove the case back by pushing down two "snaps."
See diagram below.
2.
Route wiring from the control panel through the
opening in the case back.
3.
Mount the case back to a wall or electrical box.
4.
Wire directly from the keypad's terminal block to the
terminal block on the control board. Wire functions are
marked next to terminals. Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel. See the control panel's Installation
Instructions for more complete details.
5.
Re-attach the keypad to its case back .
X
6.
Remove the clear protective film from the LCD display.
REMOTE KEYPADS
FA215KP, FA260KP, FA560KP
FA560KP
2-Line Alpha
YES (See Note 1)
YES
Speaker
NO
NO
See Note 2
See Note 2
See Note 2
See Note 2
See Note 2
See Note 3
See Note 2
Remove Case back by pushing in
the 2 "Snaps" along keypad's
bottom edge and pulling the case
apart
K3590-1V1 8/00

Advertisement

loading
Need help?

Need help?

Do you have a question about the FA215KP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for First Alert FA215KP

  • Page 1 These keys may be programmed for panic alarms or other special functions such as macros. See the control's instructions for details. The FA215KP uses the key pairs only. Function keys must be held down for at least 2 seconds to activate an alarm; key pairs activate immediately.
  • Page 2 Physical: The current keypad address will be displayed, and the FA215KP: 5-5/8"H x 4-3/8"W x 1-5/16"D cursor will be under the "tens" digit. If 10 seconds have passed with no key entry, the keypad automatically FA260KP: 6-5/8"H x 4-7/8"W x 1-5/16"D...

This manual is also suitable for:

Fa260kpFa560kp