Vent-a-Hood ISLAND Installation Instructions Manual

Liner insert

Advertisement

Quick Links

Read and Save These Instructions
All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
L116 1213A
ISLAND LINER INSERT
DUCTWORK
Page 1
U L
C
US
R

Advertisement

loading

Summary of Contents for Vent-a-Hood ISLAND

  • Page 1: Installation Instructions

    Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 • The hood must be ducted to the outdoors without restrictions. Blower Requirements • The island dual blower unit (T200) requires 8” round duct or equivalent (50 square inches), and the island cluster blower unit (T400) requires 12” round duct or equivalent (113 square inches).
  • Page 3: Installation Details

    Custom hoods may require additional specification consideration. 2) When installing the TSLE/TPSLE island liner, it is recommended that the bottom edge of the liner be located no more than 30” above the cooking surface for optimum performance. For custom liners, the recommended height off the cooking surface is dependent on the depth of the liner.
  • Page 4 Installation Details Continued 5) Remove the shipping tape that is securing the E-Z Clean shields inside the hood. Remove the E-Z Clean shields by lightly pulling each toward the end of the hood. Gently close the back draft dampers from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (one on each side of the housing).
  • Page 5 Equivalent CFM • Model Volts Amps* Sones SP@0.0" SP@0.1" SP@0.2" SP@0.3" Duct Size T200 Island Dual 1550 8" (50 in. T400 Island Cluster 1550 1100 1800 12" (13 in. * Add 0.5 amp for each halogen light. • Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more ®...
  • Page 6 VP559 3 ¼” x 10” VP521 3 ¼” x 10” to 7” VP514 7” Round VP515 8” Round MULTI-BLOWER TRANSITION M1200 STANDARD TRANSITION STANDARD ISLAND TRANSITION CLUSTER BLOWER TRANSITION 10” 12” 10” 8” 12” VP562 - 17 ½” 9” 9”...