CLEARANCES FOR MODEL 94NC
MINIMUM CLEARANCES TO COMBUSTIBLES
RESIDENTIAL SINGLE WALL CONNECTOR
BACK WALL
B
C
E
E
A
A
MODEL 94NC
22"
NOTE: All clearances are to combustibles using single wall pipe, minimum floor protector.
Minimum floor protection under unit must have an R-value of 0.30. (see page 12, 13)
NOTE: The clearances above may be reduced, follow NFPA-211 codes.
For wall exit, Floor protector must be under horizontal pipe the length between stove
and exit. Must be 2" on each side of pipe. Maintain 18" between pipe and ceiling.
(See Figure 13, measurements F & H ).
F
F
B
G
C
H
D
G
Figure 13
A
B
C
25"
8"
10.5"
23"
26"
C
D
D
E
F
8"
8"
6"
23"
8"
6"
Page 19
D
C
G
H
20"
10"
16"
12"