Euroheat Nestor Martin C23 Installation Instructions Manual

Hide thumbs Also See for Nestor Martin C23:

Advertisement

This Manual Must Always be Available to the Stove Operator
This manual must be used in
conjunction with document IN1173.
The Wood and Mutlifuel Chimney and
Installation Guide.
Euroheat
Natural Energy Company

Installation Instructions

Nestor Martin
C23,C33
C43
Q13,D33,O23,NM33
IN1210 Edition B1 October 2010
PART NUMBER
SERIAL NUMBER
Smoke
Control
Exempt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nestor Martin C23 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Euroheat Nestor Martin C23

  • Page 1: Installation Instructions

    This Manual Must Always be Available to the Stove Operator Euroheat Natural Energy Company Installation Instructions Nestor Martin C23,C33 Smoke Control Exempt Q13,D33,O23,NM33 IN1210 Edition B1 October 2010 PART NUMBER This manual must be used in conjunction with document IN1173.
  • Page 2 Since April 2002 only Registered Competent Engineers may install solid fuel fired appliances without involving the Local Authority Building Control Department. For more details contact HETAS. Euroheat would suggest only Registered Competent Engineers install Euroheat appliances. If the installer is not a registered Competent Engineer we would advise that property owners insurance company is contacted to confirm their insurance is not affected.
  • Page 3: The Model Range Explained

    Please ensure the warranty registration form is completed if you are the installer and confirm with the user that it is their responsibility to return it to Euroheat. In this way the model and its history will be recorded for reference in the future.
  • Page 4 Flue Spigot Connection deg C Nestor Martin Q13 83.4% Net 5.0kW 12pa Wood 75.9% Gross Nestor Martin Q13 78.3% Net 3.5kW 12pa Coal 71.2% Gross © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 5 Mains-powered BS EN 50291 Type A carbon monoxide alarms with fixed wiring (not plug in types) may be used as alternative applications provided they are fitted with a sensor failure warning device. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 6 Riddling Grate Air Entering Through the Plexus Control Assembly Below the Combustion Riddling Actuating Rod Chamber (Position and Shape Varies Ash Pan Door with Model) © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 7 The baffle plate is in the correct position when the small upturn on the baffle plate is against the facing wall of the flue baffle. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 8 Changing to Top Flue Connection The procedure is as if fitting the rear flue but follow the information in reverse and fit the flue spigot protector. (See page 8) © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 9 Spigot protector collar Open side MUST face to the rear of the stove Gasket Do not fit flue spigot protector collar for rear outlet option. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 10 Blanking Plate Support Bracket and Screws Blanking Plate Support Bracket Fitted to Underside of Cast Top Plate © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 11 The flue spigot can then be attached to the rear outlet using the ceramic gasket and screws supplied and the rear panel fitted back to the stove. DO NOT FIT THE SPIGOT PROTECTOR COLLAR WHEN USING THE REAR FLUE OUTLET © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 12 Gasket DO NOT FIT THE SPIGOT PROTECTOR COLLAR WHEN USING THE REAR FLUE OUTLET © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 13: Fireplace Design

    12mm of non combustible material can used. This information only applies to our range of appliances. Caution do not fit a 12mm hearth to other manufacturers products unless documentation is provided to prove hearth temperatures. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 14: Minimum Installation Clearances

    In all installations surrounding flammable materials must not exceed 65°C. Curtains and furnishings should be a minimum of 1m from the stove or the surface temperature must not exceed 65°C. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 15: General Advice

    (Expert building advice may be required). © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 16: Minimum Air Setting

    The facia plate on the plexus may have to be removed to access the adjustment screw. Any adjustment should be only undertaken by the commissioning engineer or under direction from the Euroheat Technical Department. Turn the adjustment screw clockwise to increase and anti-clockwise to decrease the minimum air setting.
  • Page 17: Remote Control Option

    The receiver box can then be placed underneath the stove, pushed back, so out of sight. full operating instructions for the remote control see the Remote Control Guide. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 18 It can also be attached to a 100mm soil pipe which may have been laid into a floor to duct air to the stove. © EUROHEAT DISTRIBUTORS (H.B.S) LTD. Oct 2010 E & OE Instructions Part number IN1210 Ed.B1...
  • Page 19: Commissioning Check List

    Continued updates occur to adapt documents to customer requirements and appliance changes. For the latest editions of all Euroheat documentation visit our web site www.euroheat.co.uk. We would request that you inform Euroheat of information which you feel is not provided in this document which would assist other users in the future.
  • Page 20 10,000 pages of technical information, spare parts, product shots, news and 1001 other things, - you will not find a more comprehensive solution to your queries, whatever time of the day. www.euroheat.co.uk Court Farm Business Park, Bishops Frome, Worcestershire WR6 5AY Pre sales:...

Table of Contents