FLIR i3 User Manual page 97

Scanners
Hide thumbs Also See for i3:
Table of Contents

Advertisement

Example for lightweight built-up cladding with defective
insulation
Outside surface temperature in ℃
Surface factor from IP17/01
Critical external surface temperature factor, after IP17/01
Insulation thickness to give this level of performance, mm
2
Local U value W/m
K
UKTA TN1 surface factor
UKTA TN1 surface factor outside
Notes to the table
1 Values of surface resistances taken from ADL2 2001, are:
Inside surface 0.13 m
Outside surface 0.04 m
These originate from BS EN ISO 6946 (BN EN ISO 6946:1997 Building components
and building elements - Thermal resistance and thermal transmittance - Calculation
method).
2 Thermal insulation used here is assumed to have a conductivity of 0.03 W/m K.
3 The difference in temperature between an anomaly and the good areas is 1.2 de-
grees on the outside and 4.1 degrees on the inside.
4 The UKTA TN1 surface temperature factor for internal surveys is:
F
= (T
– T
si
sia
so
where:
T
= internal surface temperature at anomaly
sia
T
= external surface temperature (good area)
so
T
= internal surface temperature (good area)
si
5 The UKTA TN1 surface temperature factor for external surveys is:
F
= (T
– T
so
soa
si
where T
= external surface temperature at anomaly
soa
16.4.8.4.3
Selecting maximum acceptable defect area
The allowable area of defect is a quality control issue. It can be argued that there
should be no area on which condensation, mould growth or defective insulation will
occur and any such anomalies should be included in the report. However, a commonly
used value of 0.1% of the building exposed surface area is generally accepted as the
maximum combined defect area allowable to comply with the Building Regulations.
This represents one square metre in every thousand.
Publ. No. T559580 Rev. a486 – ENGLISH (EN) – November 17, 2010
2
K/W
2
K/W
)/(T
– T
)
si
so
)/(T
– T
)
so
si
16 – Introduction to building thermography
Good area
0.3
0.95
80
0.35
Failing area
1.5
0.75
0.92
5.1
1.92
0.78
0.93
87