Side Arm Installation

COLD
MIXED
WATER
WATER
CAUTION:
Do not eliminate
the existing
temperature relief
valve
WATER HEATER
Water heater drain
NOTE: Keep bottom loop (and side arm) as low as possible.

Optional Heat Exchanger

Stainless Steel Water to Water Heat
Exchanger, Figure 2, can be used in place of
a side arm.
EMPYRE ELITE INSTALLATION AND OPERATION MANUAL • 2011
Figure 1
TEMPERING VALVE
Used for
Hot Water
bleeding air
filling system
To top of hot water tank
From bottom of hot water tank
SYMBOLS INDEX
To domestic
heating
Have a qualified electrician and
system
plumber check to ensure all
connections to the furnace are
made in accordance with the
manufacturer's specifications and
performed by qualified, licensed
Supply from
personnel in accordance with
Empyre Elite
local building codes.
furnace
Use for
Figure 2
To domestic
heating system
Hot water in
from
Empyre Elite
furnace
INSTALLATION
PUMP
BALL VALVE
THERMOMETER
BOILER DRAIN
TEMPERING OR
MIXING VALVE
IMPORTANT
When
hooking
up the Empyre
Elite to a domestic hot
water heater, a tempering
valve must be installed,
to prevent scalding hot
water from reaching the
hot water outlets.