EARTHING WORK

Earth work shall be carried out without fail in
order to prevent electric shock and noise
generation.
The connection of the earth cable to the
following substances causes dangerous
failures, therefore it shall never be done.
City water pipe, Town gas pipe, TV antenna,
lightning conductor, telephone line, etc.
INSTALLATION OF WIRELESS REMOTE CONTROL
Mounting method of battery
Uncover the wireless remote control, and
mount the batteries R03 (AAA, Micro),
2 pieces in the body regularly.
(Fit the poles with the indication
marks,
&
without fail)
How to remove and install the front panel
Removing
Remove the 2 set screws.
Move the lower part of the panel forward and
push upwards to remove.
(Remove the 3 latches in the upper section.)
Installing
Remove the air filter.
Cover the body with the front panel.
Tighten the 2 set screws.
Install the air filter. Carry out in the above order.
L3
100
80
80
80
L4
250
Open
250
Open
HOW TO RELOCATE OR DISPOSE OF THE UNIT
In order to protect the environment, be sure to pump down (recovery of refrigerant).
Pump down is the method of recovering refrigerant from the indoor unit to the
outdoor unit when the pipes are removed from the unit.
<How to pump down>
Connect charge hose to check joint.
Liquid side : Close the liquid valve with hexagon wrench key.
Gas side : Fully open the gas valve.
Carry out cooling operation. (If indoor temperature is low, operate forced cooling
operation.)
After low pressure gauge become 0.01MPa, stop cooling operation and close the
gas valve.
Battery
CAUTION
Do not use new and
old batteries together.
Cover
Set screws
Model 09, 25
Total one way length
MAX. 15m
Vertical height difference
MAX. 10m
Less than 10m : Not required
Additional refrigerant
More than 10m : 20g/m
Fixing to pillar or wall
Conventionally, operate the wireless
remote control by holding in your hand.
Avoid installing it on a clay wall etc.
Open/close and detachment / attachment of the air inlet panel
To open, pull the panel at both ends of lower part
and release latches, then pull up the panel until
you feel resistance.
(The panel stops at approx. 60˚ open position.)
To close, hold the panel at both ends of lower part
to lower downward and push it slightly until the
latch works, then push the center portion slightly.
To remove, pull up the panel to the position shown
in right illustration and pull it toward you.
To install, insert the panel arm into the slot on the
front panel from the position shown in right
illustration, hold the panel at both ends of lower
part, lower it downward slowly, then push it slightly
until the latch works and further push the center
portion slightly.
Model 12, 35
Model 18, 50
MAX. 15m
MAX. 25m
MAX. 10m
MAX. 15m
Less than 15m : Not required
Not required
More than 15m : 20g/m
Forced cooling operation
Turn on a power supply again after a while after
turn off a power supply. Then press continually
the ON/OFF button 5 seconds or more.
Unit ON/OFF button
Wireless remote control
Wood screws
ø3.5 X 16