轉性能,在您開始使用空調器之前,務請仔細閱讀本說明書。閱後應將它妥善保 維護保養 管好,以備必要時查閱。 安裝、檢查與更換過濾網 Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES Air -Conditioner. To get 使用空調器時下述狀況不屬故障 the best long-lasting performance, please read and follow this User’s Manual carefully before 出現這些情況時請立即與經銷商聯繫 using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities.
Page 23
(Apply to R32 Refrigerant Air Conditioner) mildly flammable Warning Caution Caution Caution Installation must be performed by an authorized dealer or professionally trained technician. The minimum installation height for indoor unit of air conditioner must be 180cm. The appliance is using mildly flammable refrigerant R32 and tested to comply with IEC 60335-2-40.
Page 26
This appliance incorporates an earth connection for functional purposes. The maximum refrigerant charge is as follows: Maximum refrigerant charge (kg) Model SRK25REC1 0.50 SRK35REC1 0.55 SRK50REC1 0.75 RYD012A380...
Page 28
Name of each part and its function INDOOR UNIT mildly flammable refrigerant. SERVICE CODE OUTDOOR UNIT SERVICE CODE Page72 mildly flammable refrigerant. RYD012A380...
Page 29
Name of each part and its function Operation and indication section for remote control Unit display section Operation section When each button on the remote control is pressed with the remote control pointing toward ON/OFF button the air conditioner unit a signal is transmitted. When the signal is received correctly.The unit will beep.The availability send beeline of the remote control is 5 meters.
Page 30
Indication section Temperature adjustment during AUTO Air temperature adjustment is possible even during automatic operation there are 6 levels CLEAN indicator ON/OFF TIMER indicator of adjustment possible with the button or the button. Indicates during CLEAN If you want to adjust the temperature, you should make mode operation.
Airflow direction adjustment Air-conditioner operation temperature range Please use within the following operation scope,otherwise it will start the automatic prote- ction device and resist the work of the air conditioner. Adjusting up/down air flow direction COOL operation Up/down direction can be adjusted with the AIR FLOW button on the remote control. Each time when you press this button the mode changes as follows: Outdoor temperature About 21℃to 43℃...
SLEEP TIMER operation ON TIMER operation The machine will stop automatically when reaching the set time. ON TIMER operation can be set regardless of whether the air-conditioner is running or not. To control the indoor temperature not cold during COOL, and to control the indoor temper- Example:Near set temperature around 8:00 a.m.
OFF TIMER operation SLEEP TIMER + ON TIMER operation The unit stops automatically at the end of the set period of time. When the current status Joint operation of the SLEEP TIMER function and ON TIMER function. of the air conditioner in stop, start from Procedure l, if it is under operation status, start fr- Example:If you wish it to stop after 3 hours, start operation om Procedure 2.
HI POWER /ECONO operation Setting method of the current time The current time will be set to 13:00 auto matically after the battery is installed. When en- Concerning HIGH POWER operation tering in the time setting,all the contents on the remote controller will be reset. Pressing the HI POWER/ECONO button intensifies the operation power and initiates power- Example: it is set to 10:30.
Page 35
CLEAN operation Emergency run operation About the CLEAN operation: under the “COOL” and “DRY”mode, after powering off, The “ON/OFF” button on the unit operates “ON/OFF” temporarily when the remote con- the fan of indoor machine will continue running for 0.5 hours to discharge the water in the trol is not used.
Page 36
Remote control handing When the operation fails with the remote control Replacing the batteries Are the batteries running down? If the operation still fails, handle as per The following cases signify exhausted batteries.replace old batteries with new ones. Replace the batteries with new emergency run operation.
Page 37
Maintenance At the beginning of the season At the end of the season Make certain that there are no obstac- Set the temperature setting for app- During the operational season Before maintenance les blocking the air flow around the air roximately a half day at 30℃...
Page 38
Installation, inspection and change of the filter screen Installation, inspection and change of the filter screen The air filters clogged with dust, etc., then the cooling capacity will drop, How to open the air inlet panel How to close the air inlet panel NOTE the operation noise increases, power consumption also increases.
The following situation is not a failure Has the unit been installed correctly? Suitable installation position The memory circuit of the microcomputer has After a power cut, you cannot restart, been wiped out. Use the remote control to sta- even if power has been restored. rt the operation again.
Page 40
Troubleshooting Self diagnosis function Please carry out the following checks before making a service call. The company always strives to provide the clients with more excellent service and install different judgment systems to display the following abnormal functions (the ones for abn- The air conditioner does not work at all ormal lighting and quenching type are illustrated as follows.
Page 41
Sheet, installation Please read these “safety Precautions” first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, Installation tool (necessary) Accessorles list those points which are related to the strong possibility of an installation done in error resulting in or senous injury are listed in the section.However, there is also a possibility of serious consequences in relationship to the points listed in the...
Page 42
• Neighbours are not bothered by noise or air generating from the unit. • Outlet air of the unit does not blow directly to animals or plants. SRK25REC1 • There is no risk of flammable gas leakage. Over current: 16 A •...
Page 43
The exhaust port and inspiration port behind the equipment shall be installed 10cm far away from the wall. (If the height of the fence is higher than 1.2m ar above the head, suf- ficient space shall be left between the equipment and the wall. The following sizes shall be guaranteed after the installation of the equipment.
Page 44
( 12.7):49.0~61.0N m(4.9~6.1kgf m) (profession for ① Tighten all flare nuts in the pipings both indoor R32 & R410A) and outside wall so as not to cause leak. ②Connect service valve, charge hose, manifold (profession for R32 & R410A) valve and vacuum pump as is illustrated below. ③...
Page 45
Limit of the size and length of the 25 type 35 type 50 type Preparation Liquid piping(mm) 6.35×0.8 6.35×0.8 6.35×0.8 Gas piping(mm) 9.52×0.8 9.52×0.8 12.7×0.8 Model 50 type 50 type: 16.2 Total one way length MAX. 15m MAX. 15m Vertical height difference MAX.
Page 46
The safety and comfort life period of the product is ten years. Some products also can be used after the life period. After the life period, deal of the rejectamenta, must consider the effet of the safety and the en- vironment.