B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
• Before installing, determine the following:
- Where the fireplace is to be installed.
- The vent system configuration to be used.
- Gas supply piping.
- Electrical wiring.
- Framing and finishing details.
- Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.

1. Selecting Fireplace Locations

This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement should be avoided.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
E
D
As a
room
divider
(1981 mm)
(1219 mm)
MINIMUM
Model #
BIR36
Figure 2.2
Fireplace Locations
6
F
Across a
B
C
corner
G
B
78 in.
48 in.
A
in.
72
mm
1829
Heatilator • Birmingham 36-B Installation Manual • 4059-709 • Rev H • 10/09/13
Consideration should be given to these factors before
deciding on a location.
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation/appearance may vary due to individual
design preference.
• Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1-1/2 in. air clearance at the back and
a minimum 1-1/2 in. air clearance to the sides of
the fireplace assembly must be maintained.
Chimney sections at any level require a 2 in. mini-
mum air space clearance between the framing
and chimney sections.
B
A*
In an exterior chase
or projecting into a
garage
24 in. (610 mm)
from fireplace opening to
any perpendicular wall
Along a wall
A
B
B
C
D
47 7/8
89 1/8
44 5/8
1216
2264
1133
Note:
1-1/2 in. min. air space
from fireplace to
G
combustible materials.
1/2 in. min. air space at
nailing flanges.
* 12 in. (305 mm) extra space
included for each outside air
connection. If outside air duct
has no bend, this dimension
may be reduced as long as
minimum clearances are met.
1/2 in. (13 mm) all
configurations
G
E
F
G
20 3/8
63 1/8
28 1/2
518
1603
724