How to use additional function

A
No.
Function
K1
External room sesor
K2
Centralized controller
SW05
K3
Compensate RPM
K4
Drain Pump
Indoor Temperature
K5
Compensation for Heating Mode
SW06
K6
Filter Time
K7
Hot Water Coil
K8
K9
K10
SW07
K11
External Control
K12
External Control Output
◆ AQV ** /AJN ** /AR **
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel (display) should be connected to an indoor unit to receive option.
3. Befofe installing the indoor unit, assign an option to the indoor unit according
to the airconditioning system plan.
- The default setting of an indoor unit installation option is "02000-100000-
200000-300000".
- Individual control of a remote controller(SEG20) is the function that controls an
indoor unit individually when there is more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
- When entering address option, connect remote controller receiver.
Option
SEG1
Explanation
PAGE
Indication Details Indication
Indication
and Details
0
Option
SEG7
Explanation
PAGE
Indication Details Indication
Indication
and Details
1
Option
SEG13
Explanation
PAGE
Indication Details Indication
Indication
and Details
2
Option
SEG19
Explanation
PAGE
Indication Details Indication
Indication
and Details
3
▶ If you input a number other than 0~4 of the individual control of the indoor unit(SEG20), the indoor is set as "indoor 1".
1)
The window on/off function applies to the following unit
- AJN**/AR**
26
RJ100F5HXEA_IM_E_32978A(4).indd 26
On
Disuse
Disuse
Standard
Disuse
+2°C
+5°C
1,000h
Disuse
-
-
-
-
-
-
Disuse
Thermal ON Operation ON
SEG2
SEG3
MODE
Details
Indication Details Indication Details Indication Details Indication Details
2
SEG8
SEG9
Details
Indication Details Indication Details Indication Details Indication Details
0
SEG14
SEG15
External control
External control output
Details
Indication Details Indication Details Indication Details Indication Details
0
Disuse
0
1
On/Off control
2
Off control
Window On/
1
3
Off control
1)
SEG20
SEG21
Details
Indication Details Indication Details Indication Details Indication Details
0
Off
Remark
Use
Use
Up
Only MH ** FS/FU ** , NJ *** LHX **
Use
Only MH ** FS/FU ** , NJ *** LHX **
+5°C
+2°C
Only MH *** FM **
2,000h
Except MH *** FV/FN/FB/FA/FJ **
Use
Only MH ** FS/FU ** , NJ *** LHX **
-
-
-
Use
SEG4
0
0
SEG10
0
0
SEG16
Thermo
ON
0
Operation
ON
SEG22
0
0
K1 K2 K3 K4
SW05
K5 K6 K7 K8
SW06
K9 K10 K11 K12
SW07
Indoor Unit
1(L)
F2
2(N)
F1
SEG5
SEG6
Central control
0
Disuse
0
1
Use
SEG11
SEG12
Master/Slave
0
Slave
0
1
Master
SEG17
SEG18
Buzzer
0
Use
0
1
Disuse
SEG23
SEG24
0
0
2012-10-25 오후 5:22:54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Db98032978a4Rj100f5hx seriesAj100fcj5 series

Table of Contents