Specifications; Troubleshooting Guide - Chamberlain Secure Home SH-9525AU Installation And Operating Instructions Manual

Motion sensing halogen fixture
Table of Contents

Advertisement

Range .................................................Up to 21 m (70 ft.) [varies with surrounding temperature]
Sensing Angle.....................................Up to 180°
Electrical Load ...................................Up to 250 Watt Maximum Halogen
Replacement Bulb ..............................T3 250W (or less) halogen 230 VAC
Power Requirements . ..........................230 VAC, 50 Hz
Operating Modes ...............................TEST, AUTO, and MANUAL MODE
ON-Timer . .........................................1, 5, 10 minutes
Test Timer . .........................................5 Seconds
Manual Mode Timer . .........................Dusk-to-Dawn
Ingress Protection . ..............................IP43
SYMPTOM
POSSIBLE CAUSE
Light will not come
1. Light switch is turned off.
on.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
Light comes on in
1. Light control may be installed in a relatively dark
daylight.
2. Light control is in TEST.
Light comes on for
1. Light control may be sensing small animals or automobile
no apparent reason.
2. Range is set too high.
Light stays on
1. Bulb is positioned to close to the sensor or pointed at
continuously.
2. The sensor may be picking up a heat source like an air
3. Light control is in Manual mode.
4. Sensitivity is set too high.
Light flashes on
1. Heat or light from the bulb may be turning the light
and off.
2. Light control is in the TEST mode and warming up.
3. Heat being reflected from other objects may be affecting
4. If eave installation, light shield not installed properly.
The Chamberlain Group reserves the right to discontinue products and to change specifications at
any time without incurring any obligation to incorporate new features in products previously sold.

SPECIFICATIONS

TROUBLESHOOTING GUIDE

location.
traffic.
nearby objects that cause heat to trigger the sensor.
vent, dryer vent, or brightly painted, heat-reflective
surface.
control on and off.
the sensor.
SOLUTION
1. Turn light switch on.
2. Check bulb and replace if necessary.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these
conditions.
2. Set ON-TIME switch to 1, 5, or 10 minutes.
1. Re-aim sensor. Reduce range.
2. Reduce range.
1. Reposition the bulb away from the sensor or nearby
objects.
2. Re-aim sensor. Reduce range.
3. Switch to Auto.
4. Reduce range.
1. Reposition the bulb away from the sensor.
2. Flashing is normal under these conditions.
3. Re-aim sensor. Reduce range.
4. Install light shield according to instructions.
8
201114-01

Advertisement

Table of Contents
loading