OPTIONAL POSITIONING
OF THERMOSTAT
SENSING bULb
Continued
4. The mounting clip must be a minimum of 3" from
bottom of fireplace to prevent crimping of capil-
lary. Once you have decided on a location, clean
the area thoroughly. Remove the paper backing
from the adhesive on back of mounting clip. Press
the clip into the new location so that the thermostat
sensing bulb will be positioned vertically with the
capillary at the bottom (see Figure 37). Slide the
thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Btu (Variable)
Type Gas
Ignition
Manifold Pressure
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
* For purpose of input adjustment
Btu (Variable)
Type Gas
Ignition
Manifold Pressure
Inlet Gas Pressure (in. of water)
Maximum
Minimum*
Shipping Weight
* For purpose of input adjustment
6
Capillary
Figure 37 - Positioning the Thermostat
SPECIFICATIONS
Echo Valley Oak Log
Variable Manually-Controlled
16,000/31,500
Propane/LP - Natural
Piezo
8.0" W.C. - 3.5" W.C.
14" - 10.5"
11" - 5"
38 lbs.
Meadowbrook Oak Log
Thermostatically-Controlled
26,000/39,000
Propane/LP - Natural
Piezo
8.0" W.C. - 3.5" W.C.
14" - 10.5"
11" - 5"
28 lbs.
www.desatech.com
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
Adhesive-
backed
Mounting Clip
111347-01F