Electric Starting (For EF3000iSE, EF3000iSEB):
4. Turn the engine switch to "START".
1
1 6 "START"
763-120e
NOTICE
If the engine fails to start, release the switch, wait a
few seconds, then try again. Each attempt should
be as short as possible to preserve the battery. Do
not crank the engine more than 5 seconds on any
one attempt.
5. After the engine starts, warm up the engine until
the engine does not stop when the choke knob is
returned to the original position.
6. Push the choke knob back to the original position.
TIP
When starting the engine in areas where the ambient
701-049c
temperature is below 0 °C (32 °F), the engine automat-
ically operates at the rated r/min (3,550 r/min) for three
minutes to warm up the engine regardless of the econ-
omy control switch position. The economy control unit
operates normally afterwards if the economy control
switch is turned to "ON".