Fault Diagnosis Of Major Parts - Samsung MC26AC2-07 Service Manual

Room air conditioner
Hide thumbs Also See for MC26AC2-07:
Table of Contents

Advertisement

5-4 Fault Diagnosis of Major Parts

Parts
Temp.Sensor
Heat ex. Sensor
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
(UP/DOWN swing motor)
Samsung Electronics
Measure resistance with a tester.
Normal
8KΩ~27KΩ at ambient temperature (+0°C ~ +30°C)
∞, OΩ ... open or short
Abnormal
Measure resistance between terminals (CN72) with a tester
Normal
At ambient temperature (10°C ~ 30°C)
between
Red, Yellow
Red, Blue
∞, OΩ ... open or short
Abnormal
Measure the voltage between ground and signal wire of the fan motor
Normal
between
Gray, Orange
Yellow, Orange
Abnormal
Abnormal if voltage does not change from 0V to 5V.
Normal
At ambient temperature (10°C ~ 30°C)
between
Red, Blue
Red, White
∞, OΩ ... open or short
Abnormal
Measure resistance between red wire and each terminal.
Normal
Approx. 380Ω at ambient temperature (20°C ~30°C)
∞, OΩ ... open or short
Abnormal
Diagnosis
Resistance
190±10Ω
170 ± 10Ω
Voltage
0.5V~4.5V
5V
Resistance
100±10Ω
130±10Ω
5-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc26ac2-12Mc26ac2x

Table of Contents