Outdoor Unit Installation; Wiring Connection - Samsung MC26AC2-07 Service Manual

Room air conditioner
Hide thumbs Also See for MC26AC2-07:
Table of Contents

Advertisement

Operating Instructions and Installation
3-2-2(e) Outdoor unit installation
GAS LEAK TEST
Indoor unit check point
Check for gas leak from the flare nut
connections with leak detector.

WIRING CONNECTION

Outdoor unit
3
Terminal Block
COM
1
2
3
Assembly
cable
1
2
3
Indoor unit
1
2
3
A-unit
MC26AC2-12
3-8
Two electric cables must be connected to the outdoor unit:
• The assembly cable connecting the indoor unit to the outdoor unit.
• The power cable connecting the auxiliary circuit breaker to the outdoor
unit.
1 Remove the terminal board cover on the side of the outdoor unit.
2 Connect the assembly cable to terminals 1 to 5 and connect the power cable to
therminals A to B.
√ Each wire is labelled with the corresponding terminal number.
√ Ensure the wire number of the indoor unit and the terminal number of
the outdoor unit.
3 Connect the earth wires to the earth terminals.
√ Refer to the page opposite for further details on how to check that
earthing is correct.
4 Replace the terminal board cover, carefully tightening the screw.
5 Connect the power cable to the auxiliary circuit breaker.
2
1
2
3
3
1
(L)
(N)
COM
COM
(N)
(L)
A
5
1
2
3
Earth
terminal
5
1
2
3
Earth
terminal
1
2
3
B-unit
MC26AC2-07
Indoor Unit
Outdoor Unit
MC26AC2-12
2
MC26AC2X
MC26AC2-07
(N)
Earth
E
B
terminal
Circuit Breaker
(Main Power cable)
5
1
2
3
5
Earth
terminal
5
1
2
3
5
Earth
terminal
1
2
3
C-unit
MC26AC2-07
Outdoor unit
check point
Earth
terminal
Earth
terminal
Samsung Electronics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc26ac2-12Mc26ac2x

Table of Contents