Timer Reset; Cue Options By Channel; 2.2.6.1 Cue On Fader Detent; 2.2.6.2 Auto Cue - Radio Systems Millenium-A Analog Console Installation And Operation Manual

Analog console
Table of Contents

Advertisement

Radio Systems Millenium-A Console
2.2.5
Timer Reset
The insertion of timer reset jumpers programs operation of the timer reset bus in conjunction with a selected input. The
bus will go low momentarily (100 ms) when the mixing channel is first placed into the "On" mode. Depressing the "On"
button after the channel is already turned "On", will result in another pulse of the bus.
Insert jumper S for input A to reset the timer.
Default is no jumper; no timer reset.
Insert jumper U for input B to reset the timer.
Default is no jumper; no timer reset.
2.2.6
Cue Options by Channel
2.2.6.1 Cue on Fader Detent
Enable this function to allow the operator to put the channel in cue by dropping the fader into the detent (fully down)
position, Note that a special-order fader with detent (RS Part # P&G) is required for this option.
Insert jumper K to enable cue on detent
Default is no jumper; no cue on detent
2.2.6.2 Auto Cue
Cue follows channel On/Off mode with this option enabled. The channel will automatically go into cue whenever the
channel is turned off. With this function enabled, cue still can be activated via the cue switch or fader detent.
Insert jumper J to enable auto cue
Default is no jumper insterted; no auto cue
2.2.6.3 Cue Defeat on Channel ON
Insert jumper F to cause the Cue Mode to be turned OFF whenever the channel is cycled from OFF to ON. Cue must
then be manually re-selected when the channel is turned OFF.
2.2.6.4 Cue Exclusive
Insert jumper N to cause any mix bus (which is selected) to automatically mute when cue function is engaged.
2.2.7
Cue Options by Input
Install these jumpers to disallow the channel from going into cue when a particular input is selected. This option is nor-
mally utilized for a control room mic input to avoid feedback from the cue speaker. When this option is enabled, the cue
button is automatically reprogrammed to act as a cough button (hold-to-mute) for that input.
Install jumper M for no cue on input A.
Default is no jumper; cue in input A.
Install jumper L for no cue on input B.
Default is no jumper; cue in input B.
Page 14
See Illustration B-1, Pg16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Millenium-A Analog Console and is the answer not in the manual?

Table of Contents