The function of the left bank of dipswitches
No.
Functions
1
Gas type
2
3
N/A
4
Allow adjustments of fan motor speed
(Changing the FM speed is similar to changing the manifold
pressure. See section 12-18)
5
FM+, FM++ and FM+++
6
(FM speed is increased automatically. See section 12-12))
Fan motor for combustion
Fan motor for exhaust (T-H2-DV only)
7
INPUT- (Maximum gas input is reduced automatically.
See section 12-12)
8
Allow access to operation history
(This switch is for a specialized purposes only, and therefore,
should not be used)
9
N/A
10
Model type
OFF position
No. 6
ON position
OFF position
No. 6
ON position
T-H2-DV/T-H2-OS Service Manual
ON position
Propane
Natural gas
N/A
Enable
No. 5
OFF position
0 %
+12 %
No. 5
OFF position
0 %
+7.3 %
-10%
Maximum input
EEPROM
transfer
N/A
(Default)
T-H2-DV
67
CONFIDENTIAL
Ver. 1.01
OFF position
Disable
Disable
N/A
(Default)
Disable
(Default)
ON position
+6 %
+18 %
ON position
+3.6 %
+11.4 %
Disable
(Default)
data
Disable
(Default)
N/A
(Default)
(Default)
T-H2-OS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents