Unit Operating Voltage
Range
Minimum Circuit
Ammpacity
Minimum Overcurrent
Protection Device Size
Maximum Overcurrent
Protection Device Size
No.
Volts
Phase
HP
RPM
Amps (RLA)
Amps (LRA)
No.
Volts
Phase
HP
Amps (FLA)
Amps (LRA)
No.
Volts
Phase
HP
Amps (FLA)
Amps (LRA)
1
Horsepower per Compressor
2. Amp Draw Per Motor. Multiply Value by Number of Motors to Determine Total Amps.
66
ELECTRICAL DATA - RRNL SERIES
-B036CK08 -B036CK10 -B036DK06 -B036DK08 -B036DK10 -B036JK04 -B036JK06
187-253
187-253
414-506
17/17
17/17
9
20/20
20/20
15
25/25
25/25
20
1
1
1
208/230
208/230
460
3
3
3
3 1/3
3 1/3
3 1/3
3450
3450
3450
10.4/10.4
10.4/10.4
5.8
88/88
88/88
38
1
1
1
208/230
208/230
460
1
1
1
1/3
1/3
1/3
1.3
1.3
0.6
2.3
2.3
1.1
1
1
1
208/230
208/230
460
1
1
1
1/2
1/2
1/2
2.4
2.4
1.2
5.1
5.1
2.2
414-506
414-506
187-253
9
9
25/25
15
15
25/25
20
20
40/40
1
1
1
460
460
208/230
3
3
1
3 1/3
3 1/3
3 1/3
3450
3450
3450
5.8
5.8
16.7/16.7
38
38
79/79
1
1
1
460
460
208/230
1
1
1
1/3
1/3
1/3
0.6
0.6
1.3
1.1
1.1
2.3
1
1
1
460
460
208/230
1
1
1
1/2
1/2
1/2
1.2
1.2
2.4
2.2
2.2
5.1
-B036JK08 -B036JK10
187-253
187-253
187-253
25/25
25/25
25/25
25/25
25/25
25/25
40/40
40/40
40/40
1
1
1
208/230
208/230
208/230
1
1
1
3 1/3
3 1/3
3 1/3
3450
3450
3450
16.7/16.7
16.7/16.7
16.7/16.7
79/79
79/79
79/79
1
1
1
208/230
208/230
208/230
1
1
1
1/3
1/3
1/3
1.3
1.3
1.3
2.3
2.3
2.3
1
1
1
208/230
208/230
208/230
1
1
1
1/2
1/2
1/2
2.4
2.4
2.4
5.1
5.1
5.1
Need help?
Do you have a question about the RRNL and is the answer not in the manual?