Installation Guidelines for Thermolec Electric Boilers Model B
3
Important
3.1
These instructions should be used as a general guide only. Electrical Code and local utility requirements must
be followed and take precedence over these instructions.
3.2
Thermolec electric boilers are manufactured with quality components for maximum life, durability and
minimum service. To ensure a satisfactory installation it is imperative that you read these instructions
carefully before installing and operating the heating system.
Failure to do so may result in breach of warranty.
4
Unpacking
4.1
Inspect the unit and check whether there are missing parts.
4.2
Report any damage or claims to the carrier immediately.
4.3
For all returns to be accepted they must be authorized by the manufacturer.
5
Location and dimensions
5.1
These boilers are designed for wall mounting. Please see Table 1 below for overall dimensions.
Table 1 also gives the minimum clearances to combustible material as well as recommended distances for
ease of service (e.g. replacement of tubular elements).
Models
Short Models
up to 23 kW 1ph
up to 18 kW 3ph
Long Models
up to 40 kW
TMB
5.2
The boiler room should be well ventilated as to maintain the temperature below 77°F.
5.3
The unit must be mounted level on a vertical wall with the outlet fitting on the left side of the unit.
Table 1
Dimensions and Clearances
Overall dimensions
Width Height Depth
18"
18"
9"
18"
28"
9"
13"
18"
9"
Page 3
Clearances
Front Back
Top
Right Others
36"
0"
12"
36"
0"
24"
36"
0"
12"
6"
12"
6"
12"
6"
12"