American Standard GRWF130A94A0A Installation Manual page 36

Direct vent gas fired with cast iron heat exchanger
Table of Contents

Advertisement

3.
Verify the boiler On/Off switch is On. Turn
the boiler supply water thermostat knob to the
desired setting. See Figure 1. The boiler will
begin to function automatically.
If the boiler does not light, refer to the Troublshooting
section of the Service Facts, shipped with the boiler.
4.
Clock the gas meter with the boiler operating
(determine the dial rating of the meter) for one
revolution.
5.
Find the "Sec" column that matches the
number of seconds checked to check one revo-
lution of the meter. See Table 12.
6.
Read the "Flow" column opposite the number
of seconds clocked.
7.
Use the following factors if necessary:
For 1 Cu. Ft. Dial Gas Flow CFH =
Chart Flow Reading /2
For 1/2 Cu. Ft. Dial Gas Flow CFH =
Chart Flow Reading /4
For 5 Cu. Ft. Dial Gas Flow CFH =
10X Chart Flow Reading /4
8.
Multiply the fi nal Figure by the heating value
of the gas obtained from the utility company
and compare to the nameplate rating. This
must not exceed the nameplate rating.
9.
Changes can be made by adjusting the mani-
fold pressure. To adjust the manifold pressure:
a) Turn off all electrical power to the
boiler and close the manual On/Off gas
valve.
b) Open outlet pressure port located
in gas valve. (To open valve, use a
screwdriver) See Figure 56.
c) Attach fl exible tubing from manometer
to the gas valve outlet pressure port. See
Figure 57.
d) Remove the regulator adjustment
screw cap on the gas valve for manifold
pressure adjustment. See Figure 22, item
5 and 6.
e) Open the manual On/Off gas valve and
turn on the electrical power to the boiler.
Regulator
Adjustment
Screw Cap
Figure 56
18-CG02D1-4
36
Regulator
Adjustment
Screw Cap
Outlet
Pressure
Port
Flexible Tube
From Manometer
Figure 57
Table 11
Manifold Pressure Settings
Fuel
Natural Gas
LP Gas
Table 12
Gas Flow in Cubic Feet Per Hour
2 Cubic Foot Dial
Sec.
Flow
Sec.
Flow
8
900
29
248
9
800
30
240
10
720
31
232
11
655
32
225
12
600
33
218
13
555
34
212
14
514
35
206
15
480
36
200
16
450
37
195
17
424
38
189
18
400
39
185
19
397
40
180
20
360
41
176
21
343
42
172
22
327
43
137
23
313
44
134
24
300
45
130
25
288
46
157
26
277
47
153
27
267
48
150
28
257
49
147
Outlet Pressure/
Manifold Pressure
Adjustment Screw
Outlet Pressure Port
(Manifold Pressure)
Pressure
3.6" W.C.
10.6" W.C.
Sec.
Flow
Sec.
Flow
50
144
82
88
51
141
84
86
52
138
86
84
53
136
88
82
54
133
90
80
55
131
92
78
56
129
94
76
57
126
96
75
58
124
98
73
59
122
100
72
60
120
104
69
62
116
108
67
64
112
112
64
66
109
116
62
68
106
120
60
70
103
124
58
72
100
128
56
74
97
132
54
76
95
136
53
78
92
140
51
80
90
144
50
Figure 58