VESPA LX 50 Workshop Manual page 57

Vespa lx 50
Hide thumbs Also See for LX 50:
Table of Contents

Advertisement

Vespa LX 50
Specific tooling
020333Y Single battery charger
020334Y Multiple battery charger
1)- Remove the short closed tube and the caps, then pour sulphuric acid into the cells using the type
specified for batteries, with a specific gravity of 1.26, corresponding to 30° Bé, at a minimum temperature
of 15°C until the upper level is reached.
2) - Leave to rest for at least 2 hours; then, restore the level with sulphuric acid.
3)- Within the following 24 hours, recharge with the specific battery charger (single) or (multiple) at a
density of about 1/10 of the battery nominal capacity and until the acid density is about 1.27, corre-
sponding to 31º Bé, and these values are stabilised.
4) - Once the charge is over, level the acid (by adding distilled water). Close and clean carefully.
5)- Once the above operations have been performed, install the battery in the vehicle ensuring the
connections between the wiring and the battery terminals are correct.
WARNING
- ONCE THE BATTERY HAS BEEN INSTALLED IN THE VEHICLE IT IS NECESSARY TO REPLACE
THE SHORT TUBE (WITH CLOSED END) NEAR THE + POSITIVE TERMINAL WITH THE CORRE-
SPONDING LONG TUBE (WITH OPEN END), THAT YOU FIND FITTED TO THE VEHICLE, TO
ENSURE THAT THE GASES THAT FORM CAN ESCAPE PROPERLY.
Specific tooling
020333Y Single battery charger
020334Y Multiple battery charger
Electrical system