Instructions for Installation (cont'd)
Gas Piping (cont'd)
_,WARNING
GAS PIPING
WITH
FLEXIBLE
CONNECTOR
• The appliance
and its individual
shutoff
valve
must be disconnected from the gas supply piping
system during any pressure testing of the gas sys-
GASSUPPLY P IPING
tem at test pressures in excess of 1/2 pound per
CI
square inch (3.5kPa).
• The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
i_1
shutoff valve during any pressure testing of the
MANUAL
gas supply piping system at test pressures equal
SHUTOFF
or less than 1/2 pound per square inch (3.5kPa).
VALVE
FLEXIBLE GAS CONNECTOR
AWARNING
LABELED A SCOMPLYING
WITH ANSI STANDARDS
Use pipe joint compound or teflon tape marked as
being resistant to the action of petroleum [Propane I
GROUND JOINT
(L.R)]gases.
I
UNION
(OPTIONAL)
SEDIMENT
TRAP
A sediment trap shall be installed as close to the inlet of the
3" MIN.
TRAP)
GAS
water heater as practical at the time of water heater instaUa-
CONTROL
tion. The sediment trap shall be either a tee fitting with a
CAP
VALVE
capped nipple in the bottom outlet or other device recognized
as an effective sediment trap. Ira tee fitting is used, it shall be
installed in conformance with one of the methods of installa-
tion shown.
GAS PIPING
WITH
ALL BLACK IRON
PIPE TO
GAS CONTROL
Connecting the gas piping to the gas control valve of the
water heater can be accomplished by either of the two meth-
GASSUPPLY P IPING
ods shown.
MANUAL
_
_IWARNING
SHUTOFF
Contaminants
in the gas lines may cause improper
VALVE
operation of the gas control valve that may result
in fire or explosion. Before attaching the gas line
be sure that all gas pipe is clean on the inside. To
trap any dirt or toreign material in the gas suppl_(
line, a drip leg (sometimes called a sediment trap)
must be incorporated
in the piping, The drip leg
GROUND JOINT
must be readily accessible, Install in accordance
UNION
with the "Gas Piping" section. Refer to the current
8LACKPIPE]_
GAS
edition of the National Fuel Gas Code, ANSI Z223.1
CONTROL
also referred to as NFPA 54.
VALVE
_-
DRIP LEG
L_JCJ
(SEDIMENT
3" MIN.
TRAP)
2O