Instructions for Installation (cont'd)
Locating the New Water
Combustion Air and Ventilation
Heater (cont'd)
for Appliances Located in
Unconfined Spaces
A WARNING
Unconfined Space is a space whose volume is not less than
If this water
heater will be used in beauty shops,
50 cubic feet per 1,000 Btu per hour of the aggregate input
barber shops, cleaning establishments,
or self-set-
rating ofaU appliancesinstalled in that space.Rooms com_
vice laundries with dry cleaning equipment,
it is
municating directlywith the space in which the appliances are
imperative that the water heater or water heaters
instaUed, through openings not furnished with doors, are
be installed so that combustion and ventilation
air
be taken
from outside these areas. Refer to the
considered a part of the unconfined space
"Locating The New Water
Heater"
section of this
In unconfned
spaces in buildings, infiltration may be ade-
manual and also the current edition of the National
quate to provide air for combustion, ventilation and dilution
Fuel Gas Code, ANSI Z223.1, also referred to as NFPA
154 for specifics provided concerning air required,
of flue gases. However, in buildings of tight construction (for
example, weather stripping, heavily insulated, caulked, vapor
barrier, etc.), additional air may need to be provided using the
methods described in Combustion Air and Ventilation for
AWARNING
Appliances Located in Confined Spaces, b.
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-
UIDS (VAPORS) ARE LIKELYTO BEPRESENTOR STORED
(GARAGES, STORAGE, AND UTILITY AREAS, ETC):
Combustion Air and Ventilation
Flammable liquids (such as gasoline, solvents, propane
for
Located in
(LP) or butane,
etc.), all of which emit flammable
ppuances
vapors,
may be improperly
stored or used in such
Confined
C,,
,.
areas. The gas water heater pilot light or main burner
Jpace
can ignite such vapors. The resulting flashback and fire
Confined Space is a space whose volume is less than 50 cubic
can cause death or serious burns to anyone in the
area, as well as property damage,
feet per 1,000 Bm per hour of the aggregate input rating of all
If installation
in such areas is your only option,
then
appliances installed in that space.
the installation must be accomplished in a way that
a. ALLAIR FROM INSIDE BUILDINGS:
I the pilot flame and main burner flame are elevated
from the floor at least 18 inches. While this may
(See Page 13 Figure 1, and Figure 2 below)
i reduce the chances of flammable vapors from a floor
The confined space shall be provided with two permanent
spill being ignited, gasoline and other flammable
sub-
openings communicating directly with an additional
stances
should never be stored or used in the same
room(s) of sufficient volume so that the combined volume
i room or area containing a gas water heater or other
open flame or spark producing appliance,
of all spaces meets the criteria for an unconfined space.
NOTE: Flammable
vapors
may be drawn by air currents
The total input of all gas utifization equipment installed in
ifrom other areas of the structure to the appliance,
the combined space shall be considered in making this
determination.
Each opening shall have a minimum free
area of one square inch per 1,000 BTU per hour of the
total input rating of all gas utilization equipment in the
confined space, but not less than 100 square inches. One
opening shall commence within 12 inches of the top and
one commencing within 12 inches of the bottom of the
enclosure.
ENT
FURNACE
OPENINGS
[ Figure 2 ]
!.