Single Path Hba Server Without Openvms - HP StorageWorks 4400 User Manual

Enterprise virtual array
Hide thumbs Also See for StorageWorks 4400:
Table of Contents

Advertisement

controllers. See the HP StorageWorks SAN Design Reference Guide at the following HP website for
additional information about zoning:
http://h18006.www1.hp.com/products/storageworks/ san/documentation.html
To connect a single path HBA server to a SAN switch:
1.
Plug one end of the Fibre Channel cable into the HBA on the server.
2.
Plug the other end of the cable into the switch.
Figure 26
and
Figure 27
HBA server, as well as a SAN appliance, connected to redundant SAN switches and EVA controllers.
Whereas the dual HBA server has multipath software that manages the two HBAs and their connections
to the switch, the single path HBA has no software to perform this function. The dashed line in the
figure represents the fabric zone that must be established for the single path HBA server. Note that
in
Figure
27, servers with OpenVMS can be zoned with two controllers.
2
5
8
Figure 26 Single path HBA server without OpenVMS
1. Network interconnection
2. Single HBA server (Host 1)
3. Dual HBA server (Host 2)
4. Management server
5. Multiple single HBA paths
represent configurations containing both single path HBA server and dual
1
6
10
9
HP StorageWorks 4400 Enterprise Virtual Array user guide
3
7
6. SAN switch 1
7. SAN switch 2
8. Fabric zone
9. Controller A
10. Controller B
4
26463a
57