Error Code Number Not Previously Described
Error During Function Change
Digital Mixer Temperature Motor (E61)
1. Turn digital mixer valve off for 15 seconds. Turn
back on and allow 15 seconds to reset.
2. If shower operation does not return to normal,
check and, if necessary, replace Mixer Valve.
(To be performed by competent tradesperson
only!)
3. If problem still occurs, make a note of the error
code and contact our Customer Services Team.
Digital Mixer PCB Error.
1. Turn digital mixer valve off for 15 seconds. Turn
back on and allow 15 seconds to reset.
2. If problem still occurs, make a note of the error
code and contact our Customer Services Team.
Replace batteries.
Control out of range.
Displayed if there is a signal loss between the
wireless controller and the digital mixer valve whilst a
function setting is being altered. Or, If the valve is not
ready wait for 10 seconds after entering programming
menu.
1
Press "
" to clear the display and retry the function
change.