The controller is fitted with diagnostic lights (LEDs) that assist with the set-up and maintenance of the gate.
Table 2 provides a description and purpose of the indicator lights. Refer to figure 11 below for location.
During Normal Operation
S Sens2
M Sens1
M Sens2
Sens+
Sens-
Safe CLS
Safe OPN
Com
LCK/STP
TRG
PED
Com
FRX
LIT
LED
Com
Aux 12V
Safe Com
Sol
Light
Light
Batt +
Batt -
Fi gur e 11 LED pos i t i ons
Buzzer Feedback
The VECTOR 2 controller is equipped with an onboard buzzer which is used for various features and
functions on the controller. One of the functions it provides is audible diagnostic feedback as detailed
in the table below:
Battery low condition
Multiple collision condition
Holiday lock-out enabled
NAME
STATUS
Saf CLO
ON
= Closing Safeties clear
OFF
= Closing Safeties obstructed
Saf OPE
ON
= Opening Safeties clear
OFF
= Opening Safeties obstructed
LCK/STP
ON
= System ready to operate
OFF
= System locked
TRG
ON
= Signal present
OFF
= No signal
PED
ON
= Signal present
OFF
= No signal
FRX
ON
= Signal present
OFF
= No signal
LIT
ON
= Signal present
OFF
= No signal
LED
ON
= Gate open
OFF
= Gate closed
SLOW REGULAR FLASH = Gate is opening
FAST REGULAR FLASH = Gate is closing
1 FLASH EVERY 2 SECONDS = Courtesy light latched on
2 FLASHES EVERY 2 SECONDS = Mains failure
3 FLASHES EVERY 2 SECONDS = Battery low
4 FLASHES EVERY 2 SECONDS = Collision shutdown
Tabl e 2 D es cr i pt i on of LED i ndi cat or s
PARAMETER DESCRIPTION
LED Indicator Lights
LED Indicator Lights
Buzzer emits a pulsed tone for a 5 second duration,
after the controller is activated in a battery low
condition.
Buzzer emits a continuous pulsed tone as soon as
a multiple collision shutdown is activated. The tone
will cease as soon as a valid trigger input is activated.
Buzzer emits a pulsed tone for a 5 second duration
when the controller is activated with this feature
enabled.