SpectraPure
CONFIGURING A MANUAL FLUSH SYSTEM FOR THE DRINKING WATER KIT:
SpectraPure "-MF" Systems (MC-RODI-xx-MF, CSPDI-xx-MF, CSP-xx-MF) are configured in such a way as to be incompatible
with the Drinking Water Kit. Follow these steps to convert your "-MF" system into a compatible configuration.
THIS DOES NOT WORK WITH "-AF" SYSTEMS.
1. Disconnect the blue tube, the short yellow tube and the red (or green - whichever you chose during Setup) tube
from the ASO Valve. You should find the short Flow Restrictor inside the red (or green) tube.
2. Disconnect the black tube from the RO membrane housing. Reroute it from the center hole in the back of the bracket
to the left-hand hole (as viewed from behind). Measure 3 inches of black tube above the bracket and cut the black
tube in two. That black tube from the carbon block connects to the only IN port of the ASO.
3. The OUT port of the ASO now connects to the membrane housing input, using a newly-cut length of black tubing
supplied in the kit.
4. Cut the blue tube still connected to the membrane housing down so there is only 1 inch of tubing exposed. Connect
a 1/4" Check Valve to this blue tube with the arrow pointing away from the blue tube.
5. Cut a piece of blue tube down to 2 inches. Connect one end to the the remaining free end of the Check Valve and
the other end to the ASO Valve. (Note: the arrow should be pointed towards the ASO valve.)
6. Disconnect the short yellow tubing from the Y fitting that was once connected to the ASO valve.
7. Insert the red (or green) tube with the Flow Restrictor in that end into that Y fitting.
8. Cut the longer yellow tube that is still attached to the ball valve so that it, the ball valve, and the short yellow tube
matches the length of the red (or green) tube.
9. Reconnect the yellow and red (or green) tubes to the Y fitting. Now you are ready to hook up your drinking water
kit as it is shown in the following pages.
Waste
Water Port
Check Valve
Stem Adaptor
4
®
CORRECT CONFIGURATION OF MANUAL FLUSH AND
ASO AFTER CONVERSION FOR DRINKING WATER KIT
IN port of ASO Valve
ASO Valve
CORRECT CONFIGURATION OF MANUAL FLUSH
AFTER CONVERSION FOR DRINKING WATER KIT
SpectraPure
Inc.
®
2167 East Fifth St, Tempe, Arizona 85281
Membrane Housing
OUT port of ASO Valve
Flow Restrictor Inside
480.894.5437 Call us toll-free 1.800.685.2783
Connect Yellow
Tubing to Drain
Need help?
Do you have a question about the RO Systems and is the answer not in the manual?