The connection to power supply may be carried out at the back of the appliance after
removing the protection grid. (pict.31)
For remote condensing unit, to make the connection using:
Multipolar wiring made by 11 poles with 4 section AWG 16 and 7 section AWG 12.
All wiring cables are to comply with the ratings shown on the technical specifications.
Cables are to be connected to the equipotential terminal. (pict.34)
The grounding cable is to be directly connected to a good grounding system.
(pict.35)
For remote condensing unit, to make the connection in accordance with "Safety Code for Mechanical
Refrigeration, ANSI/ASHRAE 15-1989".
Models are to be connected to remote unit condensing using:
High pressure pipe = Copper pipe 3/8" of thickness 1/25.4"
Low pressure pipe = Copper pipe 12/17" of thickness 1/25.4"
Low pressure Pipe connection is to be insulation.
On certain models, a condensation discharge
installation is necessary,
current general and local regulations as to drains are to be
complied with. (pict.36)
The guarantee will cease and the Manufacturer will not be liable for any damage to appliances or
operators arising from the non-compliance with the and tamperings to any part of the appliance
(electric, thermodynamic or hydraulic plant).
S
T
A
L
L
A
T
S
T
A
L
L
A
T
S
T
A
L
L
A
T

WIRING

PLEASE USE CERTIFIED APPROVED MATERIALS

REFRIGERATING CONNECTION

CONNECTION TO CONDENSATE DRAIN

"SAREL" or any similar type). The
I
O
N
M
A
N
U
I
O
N
M
A
N
U
I
O
N
M
A
N
Pict.36
φ 1,2" hose
A
L
-
A
L
-
U
A
L
-
Pict.31
Pict.34
Pict.35
33