Dehumidification Mode

Desired temperature < Room temperature
!
Outdoor Fan, Compressor : ON
Indoor Fan : Low speed
Desired temperature Room temperature
@
Compressor : 3 min/ON, 5 min/OFF
Indoor Fan : 3 min 30 second/ON, 4 min 30 second/OFF
Fan Speed : Low speed
Room temperature 18°C
#
Compressor : OFF
Indoor Fan : 1 min/ON, 7 min/OFF
Fan speed : Low speed
Air Discharge Direction
(1) When you turn on the unit, the flaps move to the position of keeping the room temperature comfortable.
(2) The air discharge direction is below.
Up/Down
Left/Right
Quick Mode (Powerful Cooling)
(1) Cooling condition
Fan Speed: High speed
!
Air discharge direction: Fixed
@
Set temperature: 18°C (Fixed)
#
Operation Mode: Cooling Mode
$
Compressor and Outdoor Fan
%
OFF
-1
>
>
On/Off
On/Off
ON
(Room temperature-18˚C)
0
15